2H9
1-5-21
4. Remove two screws.
5. Unhook three hooks and then remove the
original holder cover.
Figure 1-5-28
6. Move the image scanner unit (ISU) unit to
the center.
7. Detach the ISU shaft from the holder by lift-
ing it.
8. Remove the FFC.
Figure 1-5-29
Original holder cover
Screw
Screw
Hooks
FFC
ISU shaft
Holder
Image scanner
unit (ISU)