2PG/2PH
1-5-13
(2) Detaching and refitting the main charger unit
Procedure
1. Remove the drum unit (See page 1-5-12).
2. Remove the tape.
3. While pushing on the main plate (1), slide
the main charger unit (2).
Figure 1-5-17
4. Remove the main charger unit by lifting it.
5. Check or replace the main charger unit and
refit all the removed parts.
Figure 1-5-18
Main plate
Drum unit
Main charger unit
Main charger unit
Tape
Main charger unit