2L0
1-5-24
(3) Detaching and refitting the high voltage PWB
Procedure
1. Remove the developing unit (See page 1-5-
11).
2. Remove the drum unit (See page 1-5-12).
3. Remove the cassette (See page 1-5-6).
4. Remove the outer covers (See page 1-5-3).
5. Remove the power source PWB (See page
1-5-22).
6. Turn the printer with the bottom side up.
7. Remove the stop ring.
8. Remove the DU holder.
Figure 1-5-33
9. Pull out the DU bush.
10. Remove the DU cover assembly.
Figure 1-5-34
Stop ring
DU holder
DU bush
DU cover assembly
Содержание ECOSYS FS-1370DN
Страница 1: ...SERVICE MANUAL Published in April 2010 842L0111 2L0SM061 Rev 1 FS 1370DN ...
Страница 4: ...This page is intentionally left blank ...
Страница 10: ...This page is intentionally left blank ...
Страница 18: ...2L0 1 1 6 This page is intentionally left blank ...
Страница 21: ...2L0 1 2 3 1 Removing the tapes Procedure 1 Remove three tapes Figure 1 2 3 Tape Tape Tape ...
Страница 24: ...2L0 1 2 6 This page is intentionally left blank ...
Страница 57: ...2L0 1 5 5 5 Unhook seven hooks and then remove the left cover Figure 1 5 6 Left cover Hooks ...
Страница 104: ...2L0 2 1 14 Figure 2 1 21 Paper exit section block diagram EXITN Fuser unit Exit sensor Control PWB YC333 3 ...
Страница 106: ...2L0 2 1 16 This page is intentionally left blank ...
Страница 118: ...2L0 2 3 8 This page is intentionally left blank ...
Страница 122: ...2L0 2 4 4 This page is intentionally left blank ...
Страница 123: ......
Страница 124: ......