2L0
1-5-22
(2) Detaching and refitting the power source PWB
Procedure
1. Remove the left cover (See page 1-5-4).
2. Remove four connectors.
Figure 1-5-30
3. Remove four P tight screws, two screws and
ground terminal.
4. Remove the power source PWB assembly
from the high voltage PWB’s connector.
Figure 1-5-31
Connector
Connector
Connector
Connector
Power source
PWB assembly
P tight screws
P tight screws
Ground
terminal
Screws
Connector
(YC201)
High voltage PWB
Connector
(YC103)