2L0
1-5-23
5. Remove four screws and then remove the
power source plate from the power source
PWB.
6. Check or replace the power source PWB
and refit all the removed parts.
Caution: The power source film must be
installed in the specified position.
Figure 1-5-32
Power source PWB
Screws
Screws
Power source plate
Power source film
Содержание ECOSYS FS-1370DN
Страница 1: ...SERVICE MANUAL Published in April 2010 842L0111 2L0SM061 Rev 1 FS 1370DN ...
Страница 4: ...This page is intentionally left blank ...
Страница 10: ...This page is intentionally left blank ...
Страница 18: ...2L0 1 1 6 This page is intentionally left blank ...
Страница 21: ...2L0 1 2 3 1 Removing the tapes Procedure 1 Remove three tapes Figure 1 2 3 Tape Tape Tape ...
Страница 24: ...2L0 1 2 6 This page is intentionally left blank ...
Страница 57: ...2L0 1 5 5 5 Unhook seven hooks and then remove the left cover Figure 1 5 6 Left cover Hooks ...
Страница 104: ...2L0 2 1 14 Figure 2 1 21 Paper exit section block diagram EXITN Fuser unit Exit sensor Control PWB YC333 3 ...