background image

© 2020 Kymeta Corporation. All rights reserved.

20

10 April 2020

700-00064 revA Kymeta™ u7 terminal user manual — TRM-U7H and TRM-U7X configurations

10.

Placing a drop of Loctite on the thread of each screw, attach the new

power interface box and power supply

assembly

to the

ODU support plate

.

Tools:

Torque screwdriver with 0.2 N-m (2 in.-lb.) minimum rating, metric hex bit with 2.5 mm ball head and 3 in.

(minimum) extension

Hardware:

(7) BHCS, M4 × 10

Loctite:

One small drop per screw

Torque:

1.47 N-m (13 in.-lb.)

11.

Connect the new

RX OUT cable

90-degree angle side to the

antenna RX OUT port

, and the straight side to the

power interface box

, and torque to 8 in.-lb. or hand-tighten at both ends. DO NOT OVER-TORQUE RF

CONNECTORS. Apply self-sealing silicon rubber tape to the RF connectors to inhibit water ingress.

12.

Attach the

cable clamps

to hold the cables in place. If clamps fail or cannot be reclosed, replace them with the

provided clamps.

13.

Attach the

mounting handle

, if it’s been removed. Use a 1/4” ball-end hex key wrench (not provided with the kit).

14.

Connect the

power cable

and the

RX cable

to the

power interface box

. Apply self-sealing silicon rubber tape

to the RF connector to inhibit water ingress.

15.

16. Power on the terminal and do a self-check after the replacement. Refer to

700-00065-000 Kymeta™ u7

terminal installation guide TRM U7H U7X configurations

for details.

Содержание u7 Series

Страница 1: ...l User Manual Includes Kymeta u7 Antenna For Integrator and Standard u7 terminal configurations Covers TRM U7Hxx xxx and TRM U7Xxx xxx Kymeta u7 terminal configurations Document number 700 00064 000 r...

Страница 2: ...minal 11 7 2 Package the u7 terminal IDU 11 8 Clean the u7 antenna 12 9 Replace components 13 9 1 Replace the BUC 14 9 2 Replace the LNB 15 9 3 Replace the diplexer 16 9 4 Replace the data interface b...

Страница 3: ...interface box and power supply assembly accessory kit 32 13 Accessories 33 13 1 Cable kit 33 13 2 Mounting handle kit 34 14 Customer support 35 15 Revision history 35 16 Copyright and trademark infor...

Страница 4: ...For information on installing the u7 terminal refer to 700 00065 000 Kymeta u7 terminal installation guide TRM U7H U7X configurations For your safety read 700 00065 000 Kymeta u7 terminal installation...

Страница 5: ...LNB and RX IN cable and power components Cables power RX TX and Ethernet Mounting handle Indoor unit Modem The initial release of the u7 terminal requires installation and initialization upon commissi...

Страница 6: ...ronment with temperature and humidity control If the modem temperature indicator light turns yellow or red during operation the air temperature is too high for the modem and climate control measures a...

Страница 7: ...minal user manual TRM U7H and TRM U7X configurations 4 Physical connection interfaces The Kymeta u7 terminal includes the following physical connection interfaces Power out cable Antenna control cable...

Страница 8: ...nd 4 3 TX cable This N type IF cable connects the BUC in the ODU to the TX Out of the modem within the IDU The TX cable works in the frequency range from 1050 MHz to 1700 MHz and passes a 10 MHz refer...

Страница 9: ...versions 1 1 0 3240 and later allow the antenna operator to set the time of day and the day of the week when the weekly automatic reboot occurs Note that the automatic reboot cannot be disabled u7 an...

Страница 10: ...e antenna is not eligible no action is taken The u7 antenna operates normally during the OTA update process The newly installed software version takes effect on the next restart of the antenna Restart...

Страница 11: ...d Ethernet cable being mindful of pins and connectors a Ensure cable ends do not drop into water or dirt b Dry off cables and coil them into the box binding with cable ties c Do not leave adapters on...

Страница 12: ...alcohol on the antenna Clean difficult stains such as oil grease soot ink and other soils with LPS Precision Clean Multi Purpose Cleaner Degreaser at 10 to 1 dilution Connectors Use a soft bristle aci...

Страница 13: ...ll power sources to avoid possible injury from electric shock General recommendations Read all instructions carefully Pictures are provided for your reference and do not replace text instructions Alwa...

Страница 14: ...ate 4 BHCS M4 x 10 Torque 1 47 N m 13 in lb 8 Attach the BUC to the diplexer 9 Loosely bolt the diplexer to the antenna WR 75 flange with four socket head cap screws Ensure the O ring is in place corr...

Страница 15: ...lexer with the O ring facing the diplexer 4 Replace the original black O ring in the groove on the WR 75 side of the LNB 5 Connect the LNB to the diplexer with four M4 16 mm socket head cap screws fou...

Страница 16: ...head cap screws Tools US standard driver with ball head 7 64 2 Remove the O ring 3 If you are not immediately replacing the diplexer replace the antenna WR 75 flange protective cover Hardware Antenna...

Страница 17: ...e kit 4 Disconnect the 18 pin connector of the BUC control cable from the data interface box 5 Disconnect the power out cable from the back side of the data interface box 6 Remove the data interface b...

Страница 18: ...the inner and outer key of the connectors place the cabled connector squarely against the connector on the back of the data interface box and then press in until the connector engages c Screw the oute...

Страница 19: ...u7 terminal and disconnect all power sources to avoid possible injury from electric shock Assembly instructions 1 Dismount the ODU and lay it face down on a clean flat cushioned surface to protect th...

Страница 20: ...e straight side to the power interface box and torque to 8 in lb or hand tighten at both ends DO NOT OVER TORQUE RF CONNECTORS Apply self sealing silicon rubber tape to the RF connectors to inhibit wa...

Страница 21: ...2020 Kymeta Corporation All rights reserved 21 10 April 2020 700 00064 revA Kymeta u7 terminal user manual TRM U7H and TRM U7X configurations...

Страница 22: ...e Before you begin Before replacing any components familiarize yourself with 700 00065 000 Kymeta u7 terminal installation guide TRM U7H U7X configurations section Safety and handling instructions Pri...

Страница 23: ...L screw and bolt the screw 3 halfway 6 Pull push the last hole into alignment to insert the last screw if needed Be sure to apply Loctite 7 Tighten all four screws in cross pattern 8 Check that all s...

Страница 24: ...e RX cable BLUE to the power interface box and finger tighten 2 Connect the TX cable RED to the BUC Use a torque wrench with an 8 1 in lb break over 3 Screw an N type to F type adapter to the RX IN po...

Страница 25: ...00064 revA Kymeta u7 terminal user manual TRM U7H and TRM U7X configurations 9 Wrap 1 2 of the electrical tape around each of the RX and TX connectors on the ODU side of the u7 terminal to protect fr...

Страница 26: ...10 Kymeta u7 terminal configuration diagram If your Kymeta u7 terminal K LO configuration includes iDirect Velocity X7 connect the Ethernet cable to any modem port in range from 5 to 8 If your Kymeta...

Страница 27: ...cing any components on the u7 terminal make sure you have all the required tools Tool diagram Tool description 3 mm ball end Allen driver M3 ball end Allen driver 2 Philips screwdriver US standard dri...

Страница 28: ...configurations Torque screwdriver with 1 47 N m 13 in lb minimum rating Metric hex bit 2 5 mm ball head with 3 in minimum extension Metric hex bit 5 mm ball head with 3 in minimum extension M3 ball h...

Страница 29: ...versal Series BUC FRU 400 00006 000 Universal N type connector LNB FRU 400 00007 000 Ku band Diplexer FRU 400 00018 000 Mounting handle FRU kit 400 00025 000 Data interface box accessory kit 400 00026...

Страница 30: ...hillips head screw PHS M4 X 20 471 00024 000 1 Button head cap screw BHCS M4 x 8 471 00016 000 4 Socket head cap screw SHCS M4 x 10 471 00018 000 4 12 2 LNB replacement hardware Hardware diagram Hardw...

Страница 31: ...acement hardware Hardware diagram Hardware description Part number Quantity Ku band diplexer 430 00302 000 1 Antenna WR 75 flange protection cover 430 00518 000 1 O ring 455 00006 100 1 12 4 Data inte...

Страница 32: ...it Hardware diagram Hardware description Part number Quantity Power interface box and power supply assembly 820 00480 000 1 RX OUT cable to connect the power interface box to the antenna RX OUT port 1...

Страница 33: ...cable is available in a length of 7 62 m 25 ft To ensure performance of the system across the full operational range Kymeta recommends using the following IF cable types for the RX cable and TX cable...

Страница 34: ...2020 Kymeta Corporation All rights reserved 34 10 April 2020 700 00064 revA Kymeta u7 terminal user manual TRM U7H and TRM U7X configurations 13 2 Mounting handle kit...

Страница 35: ...25 6638 Monday to Friday 07 00 18 00 PT UTC 8 15 Revision history Revision Change A Initial document 16 Copyright and trademark information 2020 Kymeta Corporation All Rights Reserved KYMETA KYMETA CO...

Отзывы: