16
. ELECTRICAL EQUIPMENT
16-14
VITALITY 50
Inspect the ignition coil with an ignition
coil tester.
1. Turn the changeover switch to 12V and
connect the ignition coil to the tester.
2. Turn the power switch ON and check the
spark from the watch window.
~
Good : Normal and continuous spark
~
Faulty : Weak or intermittent spark
A.C. GENERATOR
Exciter Coil/Pulser Coil Inspection
Remove the met-in box and center cover.
(
13-5)
Disconnect the A.C. generator wire
connector.
Measure the pulser coil resistance between
the blue/yellow wire and ground.
Resistance
(20
~
):
2-Stroke: 80
~
160
Ω
Resistance
(20
~
):
4-Stroke: 118.1
~
118.2
Ω
Blue/Yellow
Follow the ignition coil tester
manufac-turer‘s instructions.
The test is performed at both conditions
that the ignition coil is cold and hot.
This test is performed with the stator
installed in the engine.
Blue/Yellow
Содержание Vitality 50
Страница 20: ...2 GENERAL INFORMATION 2 15 VITALITY 50 WIRING DIAGRAM 2 STROKE ...
Страница 21: ...2 GENERAL INFORMATION 2 16 VITALITY 50 WIRING DIAGRAM 4 STROKE ...
Страница 47: ...2 GENERAL INFORMATION 2 42 VITALITY 50 Faulty ignition coil ...
Страница 66: ...4 LUBRICATION SYSTEM 4 1 VITALITY 50 LUBRICATION SYSTEM 2 STROKE ...
Страница 67: ...4 LUBRICATION SYSTEM 4 2 VITALITY 50 4 STROKE Oil Pump Oil Filter Screen Crankshaft Rocker Arm Shaft ...
Страница 92: ...6 4 STROKE CYLINDER HEAD VALVES 6 1 VITALITY 50 ...
Страница 107: ...7 CYLINDER HEAD 2 STROKE CYLINDER PISTON 7 1 VITALITY 50 2 STROKE Torque 1 0 1 2kg m Torque 1 1 1 7kg m cold ...
Страница 108: ...7 CYLINDER HEAD 2 STROKE CYLINDER PISTON 7 2 VITALITY 50 4 STROKE ...
Страница 126: ...8 A C GENERATOR 8 1 VITALITY 50 Torque 3 5 4 0kg m Torque 0 8 1 2kg m Torque 0 6 1 0kg m Torque 0 8 1 2kg m ...
Страница 150: ...10 FINAL REDUCTION 10 1 VITALITY 50 ...
Страница 159: ...11 CRANKCASE CRANKSHAFT 11 1 VITALITY 50 2 STROKE Torque 0 8 1 2kg m ...
Страница 160: ...11 CRANKCASE CRANKSHAFT 11 2 VITALITY 50 4 STDROKE ...
Страница 173: ...12 CARBURETOR 12 1 VITALITY 50 ...
Страница 259: ...16 ELECTRICAL EQUIPMENT 16 17 VITALITY 50 ELECTRIC STARTER Starter Motor Starter Relay ...
Страница 263: ...16 ELECTRICAL EQUIPMENT 16 21 VITALITY 50 ...
Страница 275: ...18 SPECIFICATIONS 18 1 4 STROKE ...