10
. FINAL REDUCTION
10-8
VITALITY 50
After installation, fill the transmission case
with the specified oil. (
3-5)
Specified Gear Oil
: SAE90#
Oil Capacity: at disassembly
:
0.12 liter
at change:
0.11 liter
Install and tighten the oil check bolt.
Torque
: 1.0 1.5kg-m
Start the engine and check for oil leaks.
•
Place the motorcycle on its main stand
on level ground.
•
Check the sealing washer for wear or
damage.
Drain Bolt
Oil Check Bolt Hole/Filler
Содержание Vitality 50
Страница 20: ...2 GENERAL INFORMATION 2 15 VITALITY 50 WIRING DIAGRAM 2 STROKE ...
Страница 21: ...2 GENERAL INFORMATION 2 16 VITALITY 50 WIRING DIAGRAM 4 STROKE ...
Страница 47: ...2 GENERAL INFORMATION 2 42 VITALITY 50 Faulty ignition coil ...
Страница 66: ...4 LUBRICATION SYSTEM 4 1 VITALITY 50 LUBRICATION SYSTEM 2 STROKE ...
Страница 67: ...4 LUBRICATION SYSTEM 4 2 VITALITY 50 4 STROKE Oil Pump Oil Filter Screen Crankshaft Rocker Arm Shaft ...
Страница 92: ...6 4 STROKE CYLINDER HEAD VALVES 6 1 VITALITY 50 ...
Страница 107: ...7 CYLINDER HEAD 2 STROKE CYLINDER PISTON 7 1 VITALITY 50 2 STROKE Torque 1 0 1 2kg m Torque 1 1 1 7kg m cold ...
Страница 108: ...7 CYLINDER HEAD 2 STROKE CYLINDER PISTON 7 2 VITALITY 50 4 STROKE ...
Страница 126: ...8 A C GENERATOR 8 1 VITALITY 50 Torque 3 5 4 0kg m Torque 0 8 1 2kg m Torque 0 6 1 0kg m Torque 0 8 1 2kg m ...
Страница 150: ...10 FINAL REDUCTION 10 1 VITALITY 50 ...
Страница 159: ...11 CRANKCASE CRANKSHAFT 11 1 VITALITY 50 2 STROKE Torque 0 8 1 2kg m ...
Страница 160: ...11 CRANKCASE CRANKSHAFT 11 2 VITALITY 50 4 STDROKE ...
Страница 173: ...12 CARBURETOR 12 1 VITALITY 50 ...
Страница 259: ...16 ELECTRICAL EQUIPMENT 16 17 VITALITY 50 ELECTRIC STARTER Starter Motor Starter Relay ...
Страница 263: ...16 ELECTRICAL EQUIPMENT 16 21 VITALITY 50 ...
Страница 275: ...18 SPECIFICATIONS 18 1 4 STROKE ...