12
. CARBURETOR
12-25
VITALITY 50
FLOAT LEVEL INSPECTION
Measure the float level at the location of the
main jet (just contacting the float valve).
Float Level
: 20.5
±
1.0mm
Replace the float if the level is incorrect.
Check the operation of the float and then
reinstall the float chamber.
Datum plane
VACUUM CHAMBER ASSEMBLY
First install the jet needle and spring into
the vacuum chamber and then install the
needle holder.
Install the vacuum piston into the carburetor
body.
Install the spring.
Install the vacuum chamber cover and
tighten it with the two screws.
Vacuum Piston
Spring
Needle Holder
Vacuum Piston
Jet Needle
•
Be careful not to let the diaphragm slip.
•
If the diaphragm cannot be positioned
correctly because of expansion, dry the
diaphragm before installation.
Datum Plane
Содержание Vitality 50
Страница 20: ...2 GENERAL INFORMATION 2 15 VITALITY 50 WIRING DIAGRAM 2 STROKE ...
Страница 21: ...2 GENERAL INFORMATION 2 16 VITALITY 50 WIRING DIAGRAM 4 STROKE ...
Страница 47: ...2 GENERAL INFORMATION 2 42 VITALITY 50 Faulty ignition coil ...
Страница 66: ...4 LUBRICATION SYSTEM 4 1 VITALITY 50 LUBRICATION SYSTEM 2 STROKE ...
Страница 67: ...4 LUBRICATION SYSTEM 4 2 VITALITY 50 4 STROKE Oil Pump Oil Filter Screen Crankshaft Rocker Arm Shaft ...
Страница 92: ...6 4 STROKE CYLINDER HEAD VALVES 6 1 VITALITY 50 ...
Страница 107: ...7 CYLINDER HEAD 2 STROKE CYLINDER PISTON 7 1 VITALITY 50 2 STROKE Torque 1 0 1 2kg m Torque 1 1 1 7kg m cold ...
Страница 108: ...7 CYLINDER HEAD 2 STROKE CYLINDER PISTON 7 2 VITALITY 50 4 STROKE ...
Страница 126: ...8 A C GENERATOR 8 1 VITALITY 50 Torque 3 5 4 0kg m Torque 0 8 1 2kg m Torque 0 6 1 0kg m Torque 0 8 1 2kg m ...
Страница 150: ...10 FINAL REDUCTION 10 1 VITALITY 50 ...
Страница 159: ...11 CRANKCASE CRANKSHAFT 11 1 VITALITY 50 2 STROKE Torque 0 8 1 2kg m ...
Страница 160: ...11 CRANKCASE CRANKSHAFT 11 2 VITALITY 50 4 STDROKE ...
Страница 173: ...12 CARBURETOR 12 1 VITALITY 50 ...
Страница 259: ...16 ELECTRICAL EQUIPMENT 16 17 VITALITY 50 ELECTRIC STARTER Starter Motor Starter Relay ...
Страница 263: ...16 ELECTRICAL EQUIPMENT 16 21 VITALITY 50 ...
Страница 275: ...18 SPECIFICATIONS 18 1 4 STROKE ...