![KYLAND KIEN8000 Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/kyland/kien8000/kien8000_user-manual_2014788033.webp)
第
5
章
PING Command
The IP address of the testing computer 1 is 192.168.100.10 and the 2 is
192.168.100.11.On the testing computer 1, run “cmd” in the WIN2000 operating
system or “command” in the WIN98/95 operating system from “Run” in the “Start”
menu. Send “ping 192.168.100.11 –l 1000 –t”. (-1 means byte number of the sent data
package; -t means continuously sending data). On the testing computer 2, run “cmd” in
the WIN2000 operating system or “command” in the WIN98/95 operating system from
“Run” in the “Start” menu. Send “ping 192.168.100.10 –l 1000 –t”. If switches run
normally, the testing computer 1 returns “Reply from 192.168.100.11
:
bytes=1000
time<10ms TTL=128” and the 2 returns “Reply from 192.168.100.10
:
bytes=1000
time<10ms TTL=128”, and the counted package loss rate is zero checked by the CTL
+C command ten minutes after running.
-