Section 5:
Testing
Methods
1.13
Self-Check
When the power is connected, all service indicators(except for POWER OUT) on the
front panel will flash one time, which means normal running of these ports. Later on,
the RUN indicator is on.
1.14
Testing Ethernet Ports
As shown in Figure 5-1, KIEN8000 is powered up and any two Ethernet ports are
connected to the uplink Ethernet ports of KIEN1000-PD(powered device) by cross-
over or straight-through cables. Any port of the PD is connected to the Ethernet port of
PC. Ping command is sent while they can be ping each other without packet loss.
Meanwhile, the 10/100M light of KIEN8000 should be always on and LNK/ACT light
is blinking, POWER OUT is always on. All these can prove the tested hardware is
working normally. The same way is used for other Ethernet ports (Please refer to the
example for PING command operation).
测试计算机2
测试计算机1
Figure 5-1 Testing Ethernet Ports
-
22
-