3 Mounting
3.1 Dimension Drawing
Figure 2 Dimensions (unit: mm)
199.4
220
210
38 12.9
74
62
32
●
●
Caution:
As part of the heat dissipation system, the switch housing becomes
hot during operation. Please use caution when coming in contact
and avoid covering the switch housing when the switch is running.
The figures in this manual are only for reference.
3.2 Mounting Modes and Steps
The series devices support panel mounting, and shoud be installed in the
assembled cabinet that is “open type”. Before installation, make sure that the
following requirements are met.
1) Environment: temperature (-40
℃
to 75
℃
), ambient relative humidity (5% to
95%, non-condensing).
2) Power requirement: The power input is within the voltage range of the switch.
3) Grounding resistance: <5
Ω
4) No direct sunlight, distant from heat source and areas with strong electromagnetic
interference.
5) Devices are to be installed in an authority certified IP54 rating or even higher
cabinet and accessible only by the use of a tool.