G.  FEATURES OF THE SOLAR VACUUM TUBES

• 

Consists of two glass tubes (inner 

and outer) manufactured from 

Borosilicate glass.

• 

The outer tube is transparent 

allowing light rays to pass through it 

with minimum reflection.

• 

The inner tube is coated with a solar 

selective coating, which provides 

excellent solar radiation absorption.

• 

The tops of the two tubes are fused 

together and the air extracted, 

which forms a vacuum.

• 

To maintain the vacuum between the two tubes a barium layer is used, which 

provides a clear visual indication of the vacuum status. The silver coating will turn 

white if the vacuum is lost.

• 

The tubes are installed onto a frame and the tops of the tubes inserted into a 

manifold. Both are made from anodized aluminum.

H.  ROOF LOCATION OF A SOLAR SYSTEM

1.   Roof location and pitch

•  For optimum performance the solar flat plate collector 

panel/s or solar vacuum tubes with frame, need to face 

the equator (facing north for Southern Hemisphere 

installations). Installation on angles of up to 45ໍ away from 

the equator do not have a major effect on the annual solar 

output, consequently roof locations which face less than 

45

°

 away from the equator are acceptable. Solar radiance 

from the sun begins at about 10.00 until 16.00 and at its 

peak between 12.00 and 14.00.

• 

 If the solar flat plate collector panel/s or solar vacuum tubes are installed with an 

east facing bias, the best solar capture is achieved in the morning and if installed 

with a west facing bias, in the afternoon.

• 

The installation location should not be subject to excessive shading from trees 

and adjacent buildings and particularly between 9.00 and 15.00. Shadows are 

longer in winter than in summer so a location that is free of shadows in summer 

may have some shadows in winter.

• 

The solar flat plate collector panels or solar vacuum tubes should be installed 

on a roof pitch greater than 8ໍ and less than 30ໍ. Where the roof pitch is greater 

than 30ໍ, the installation will require additional support to prevent it from moving 

downwards when installing and after installing. If the pitch is less than 8ໍ, the 

installation will require a mounting frame to increase the pitch to above 8ໍ. 

Installations below 8ໍ do not thermosyphon effectively and the solar flat plate 

collector panel/s or vacuum tubes will not clean properly when it rains.

12 set

16 set

20 set

PERFECT

ORIENTATION

ZONE

GOOD

ORIENTATION

ZONE

GOOD

ORIENTATION

ZONE

N

20˚E

20˚W

40˚W

40˚E

S

E

W

Содержание Kwiksol

Страница 1: ...INSTRUCTION INSTALLATION WARRANTY MANUAL...

Страница 2: ...ES 7 H ROOF LOCATION OF A SOLAR SYSTEM 7 I INSTALLATION OF A SOLAR WATER HEATER SYSTEM 9 J FILLING A SOLAR SYSTEM 17 K DRAINING AN INDIRECT SOLAR SYSTEM 18 L GENERAL MAINTENANCE OF THE SOLAR SYSTEM FO...

Страница 3: ...liquid if heated becomes less dense and rises upwards The heated transfer fluid either water direct system or propylene glycol indirect system in the solar flat plate collector panel s or manifold of...

Страница 4: ...on the thermostat must be lower than the maximum temperature attainable on the solar flat plate collector panel s or manifold of the solar vacuum tubes Pumps must be installed in accordance with the...

Страница 5: ...element in the event the solar energy is not strong enough to heat the water to the required set temperature i e on overcast days and in the evening A pipe set is supplied with silicone inserts to co...

Страница 6: ...mosyphon circulation method or as a split system themosyphon or pumped circulation methods Number and Size of Solar Flat Plate Collector Panel to Use SOLAR WATER HEATER NUMBER OF PANELS ENERGY TRANSFE...

Страница 7: ...y roof locations which face less than 45 away from the equator are acceptable Solar radiance from the sun begins at about 10 00 until 16 00 and at its peak between 12 00 and 14 00 If the solar flat pl...

Страница 8: ...ok This procedure is not relevant for the fame for the solar vacuum tubes Where two solar flat plate collector panels are to be installed proceed as follows for both a close coupled and split systems...

Страница 9: ...Kwikot Pressure Control Valve Kwikot Vacuum Breakers on both the cold water supply and the hot water draw off Kwikot Drain Cock and Kwikot 400kPa Safety Valve The solar water heater and solar flat pl...

Страница 10: ...nstallation Warranty Manual 1 Thermosyphon Close Coupled System method Direct Indirect systems with flat plate collector panel s THEMOSYPHON SPLIT SYSTEM METHOD DIRECT INDIRECT SYSTEMS WITH SOLAR FLAT...

Страница 11: ...ED SYSTEM INSTALLATION DIAGRAM REAR VIEW 1 16 19 17 12 16 15 18 15 2 5 8 6 7 4 16 Once the solar flat plate collector panel s have been installed on the roof the solar water heater has to be installed...

Страница 12: ...acuum Breaker Hot Side Thermostatic Mixing Valve Hot Water Feed to Taps Balanced Pressure Solar Collector Panels Roof Mounting Brackets for Solar Collector Panel 1 2 3 4 5 6 7 8 9 10 PRODUCT DESCRIPTI...

Страница 13: ...w from Drip Tray Expansion Valve 100kPa 11 12 13 14 15 16 17 18 19 20 HOT WATER COLD WATER REAR VIEW 1 15 21 16 12 15 17 2 5 8 6 7 4 15 13 5 6 14 14 12 10 10 11 15 1 3 20 15 19 18 9 9 INDIRECT THERMOS...

Страница 14: ...Electrical Circulating Pump Hot Water Feed to Solar Water Heater Solar Collector Panels AutoVentValve Vacuum Breaker Cold Side Vacuum Breaker Hot Side Thermal Pipe Lagging Differential Thermostat Saf...

Страница 15: ...18 Solar Water Heater Direct 400kPa Kwikot Drain Cock Cold Water Feed to Vacuum Tube Manifold Multi Pressure Control Valve 400kPa Vacuum Breaker Cold Side Vacuum Breaker Hot Side Thermostatic Mixing...

Страница 16: ...water heater cradle available from Kwikot at the marked position d Place the solar water heater into the cradle 5 Important Installation Information a In an Indirect system installation the solar wat...

Страница 17: ...s system The dilution ratio s as follows Ambient temperatures in winter 5 C to 8 C one part Propylene Glycol to three parts water i e Propylene Glycol 1lt with 3lts of water Ambient temperatures in wi...

Страница 18: ...advisable to measure how much heat transfer fluid emptied out in the bucket as this will provide a good indication of how much has to be replaced into the system Never allow the heat transfer fluid to...

Страница 19: ...except occasional dripping from the overflow pipe on the Safety Valve shut off the water supply to the solar water heater at either a shut off valve at or before the solar water heater or at the wate...

Страница 20: ...ate of the warranty period Where Kwikot supplies an auxiliary component from another manufacturer that manufacturer s warranty period and conditions will apply If Kwikot carries out repairs or replace...

Страница 21: ...has been designed and manufactured to work at optimum performance by using genuine Kwikot parts Should these parts be replaced with non genuine Kwikot parts whilst the solar water is still under warr...

Страница 22: ...below 5 C is not covered by the warranty Any damage caused to the solar collector panels due to an incorrect dilution of propylene glycol or water being used in an Indirect System will not be covered...

Страница 23: ...olar System Installed tick appropriate blocks on table below b Solar Water Heater Serial Number Code and Installation Date Serial Number ____________________________ Code _____________________________...

Страница 24: ...OFFICE PO Box 47366 Greyville Durban 4023 Tel 031 574 8700 Fax 031 574 8750 Email service kwikotkzn co za KWIKOT PTY LTD EASTERN CAPE DIVISIONAL BRANCH OFFICE PO Box 29142 Sunridge Park Port Elizabeth...

Страница 25: ...Company Name ____________________________ Physical Address ________________________________________________________________________ ID Number _________________________________________________________...

Страница 26: ...26 Kwiksol Instruction Installation Warranty Manual POSTAGE STAMP KWIKOT PTY LTD PO BOX 389 Benoni 1500...

Страница 27: ...Kwiksol Instruction Installation Warranty Manual 27...

Страница 28: ...28 Kwiksol Instruction Installation Warranty Manual 11 2016...

Отзывы: