IV / In the Package
A.
B.
Check for damage not apparent upon delivery of unit (if damage is noted and is severe
enough to warrant a claim, call freight company immediately and file a claim).
Check to make sure that there are 3 duct collars attached to the KCA unit. 2 Duct
collars will be attached to the KCW unit.
After you have uncrated your new CeilingMaster, you should check the following:
Page 4
III / Introduction
If you are reading this, then you have made the decision to purchase the smallest most
powerful ceiling mounted unit made, KwiKool’s CeilingMaster.
The information in this manual will explain how to assemble, install and operate the
KCA/KCW ceiling mounted unit. Please read the complete manual before proceeding to try
an install the unit. If you have any questions after reading the manual, please feel free to
contact our technical support department at:
1-800-KWIKOOL (800-594-5665)
.
NOTE: All Electrical and Mechanical work should be completed by a licensed profes-
sional and should be completed in accordance with local building codes. Diversity
Industries, Inc. is not responsible for injuries, and/or damages for use or misuse of unit,
improper installation, or failure to follow local building codes.
V / Installation
Things you will need for installation:
B.
Before you begin installation, it is important to verify that you have sufficient clearance
for the unit in the space above the ceiling for the unit to fit. The most important
clearance items are the condenser discharge and the condenser inlets. You need a
minimum clearance of 24” for the condenser inlets and sufficient area and/or clearance
to run duct if necessary to move the heat to another area or space. The evaporator
needs no clearance accept the amount of clearance needed to attach the duct work
and the space needed for the duck work.
NOTE: The KCA model uses the space above the ceiling for the condenser supply
and return. It is mandatory that consideration be made for movement of the heat so
as not to short cycle the condenser by allowing the heat to be sucked directly into
the condenser inlet(s). If you have questions about this please call KwiKool’s
technical support at: 1-800-KWIKOOL (800-594-5665)
A.
Four (4) mounting rods (all-thread) with mounting hardware and vibration isolators
all rated to handle the load requirements.
Power cable and connector to mount unit.
1/4” Rated drain line with 2 clamps. For distance needed to reach hard pipe drain
line.
1.
2.
3.