K U N S T S T O F F – V E R B I N D U N G S – T E C H N I K G M B H
Stand: Okt-12
Werkering 6 – 33609 Bielefeld – Tel. 0521 / 93207-0 – Fax 0521 / 93207-11
Kap. 7 – Seite 4
7.2.3
Connections
1
16-pole socket board for the ERW connection cable
(see 7.6.6 EWS connection cable circuit diagram for the pin assign-
ments)
2
Ready / fault message to an upstream control unit,
(5-pole, 270°) (see 7.6.7 fault circuit diagram for the pin assignments)
3
Type plate with serial number
Photo 4: EWS generator, connections on the rear side
7.2.4
Fuse protection
1
Mains cable
2
Mains fuse,
10 A, for 1000 W and
12 A, for 1500 W
3
Secondary fuse,
16A, flink
Photo 5: Fuse protection
7.2.5
Back-up fuse
Generator Back-up fuse
Cable length
Cable cross-section Socket
1 kW
1.5 kW
16 A
> 5m
1.5mm²
2.5mm²
Schuko 16A, 3-
pole
Table1: Back-up fuse