background image

 

 

TYPE 9101                                                07/2014                                                        4      

 

 
The TYPE 9101 appliance has been designed for solid fuel combustion in periodic feed rates and 
is  intended  for  cooking  in households  and/or  for  heating  the  space  in  which it  is  situated, accor-
ding to  the  ČSN  EN  12815:2002  Standard  as  amended  by A1:2005.  The  appliance can be  con-
nected to a chimney from the back, both sides or from the top by means of a hole in the hob-top 
(Figure 1).  
The appliance is suitable for short operational periods, so it is not possible to set the permanent-
heat process with a shortest interval of fuel supply of 10 hours.     
 

Appliance 

 

 

 

 

 

TYPE 9101  

Nominal heat output (NHO) 

 

 

 

wood 

 

coal 

 

summer mode 

 

 

 

 

6 kW 

 

6 kW 

 

winter mode   

 

 

 

 

6 kW 

 

6 kW 

Efficiency with NHO 

 

 

 

 

73,3% 

Average flue gas temperature with NHO 

 

 

275°C 

Flue gas mass flow rate with NHO   

 

 

8,3 g/s 

Average concentration of CO with NHO (with O

2

 = 13%) 

0,11 %

 

Minimum chimney draught  

 

 

 

12 Pa 

Working surface height (distance from floor to hob top panel)  850 mm 

Appliance width    

 

 

 

 

325 mm 

Appliance depth    

 

 

 

 

620 mm 

Exhaust branch diameter   

 

 

 

120 mm 

Height to flue centre  

 

 

 

 

700 

± 

0.5 mm 

Hob-top panels area  

 

 

 

 

0.12 m

Tested fuel 

 

 

 

 

 

wood: size 200-265 mm 

Average wood consumption 

 

 

 

2 kg/h 

Weight    

 

 

 

 

 

100 kg       

 

Dimensions of the Fire Box 

Width 

x

 Height 

х

 Depth (summer regime) 

 

 

190 х 220 x 270 mm 

Width 

x

 Height 

х

 Depth (winter regime) 

 

 

190 х 360 x 270 mm 

 

Fire grate, Width 

х

 

Depth (upper)   

 

 

185 х 285 mm 

Fire grate, Width 

х

 

Depth

 

(bottom)   

 

 

140 х 240 mm 

 

 

Stokehole, Width 

x

 Height  

 

 

 

192 х 130 mm 

 

Accessories 

Poker 

 

 

 

 

                         1 piece 

 

Technical Specifications

 

Содержание TYPE 9101

Страница 1: ...TYPE 9101 07 2014 1 TYPE 9101 OPERATION MAINTENANCE MANUAL INSTALLATION MANUAL SOLID FUEL RANGE COOKER...

Страница 2: ...TYPE 9101 07 2014 2...

Страница 3: ...forbidden to use the appliance if it is damaged unfit for its function Any contravention of the operating conditions may cause damage to some parts of the appliance It is recommended not to overload t...

Страница 4: ...ummer mode 6 kW 6 kW winter mode 6 kW 6 kW Efficiency with NHO 73 3 Average flue gas temperature with NHO 275 C Flue gas mass flow rate with NHO 8 3 g s Average concentration of CO with NHO with O2 13...

Страница 5: ...s or from the top by means of a hole in the Hob Top Fig 1 and 5 The hotplate lid is packaged separately behind the rear side of the appliance for ease of transportation After the appliance has been un...

Страница 6: ...of increased room of the combustion chamber should be used Combustion then takes place on the lower grate which can be handled using a lever Figure 3 Raking Raking must be done so the unburned fuel fa...

Страница 7: ...e graphic representation of the control is made using triangles and the lever under the symbol means slow burning air supply is closed and contrariwise the lever below the symbol means fast burning ai...

Страница 8: ...m steel The front of the hob top above the combustion chamber is especially intended for fast cooking while the rear part has a lower temperature and is suitable for slow cooking and keeping meals war...

Страница 9: ...recommends that their range cooker should be covered by the uninsulated lid only after the cooker ceased its operation That means when the food is being cooked on the hob and fuel is still being adde...

Страница 10: ...air rose let fire burn out Fire in the chimney do not use water to extinguish the fire close all of the air intakes cover the chimney if possible contact a qualified chimney sweep service to evaluate...

Страница 11: ...cap and to attach the flue branch without the ring and use the delivered blank cover to close the rear outlet A chimney with a sufficient draught is absolutely essential for correct appliance operati...

Страница 12: ...l The protective baffle plate shall overlap the protected material up to the nearest wall ceiling made of a fireproof material however not less than 300 mm at the upper side and 150 mm at the lateral...

Страница 13: ...TYPE 9101 07 2014 13 Flue gas ducting connection to the chimney valid for Czech Republic correct wrong Figure 6...

Страница 14: ...ove installation and operation instructions for the appliances primarily comply with the Czech regulations and may not comply fully to individual national regulations at place of installation and use...

Страница 15: ...TYPE 9101 07 2014 15...

Страница 16: ...1 07 2014 16 Producer KVS EKODIVIZE a s Plant Dvorce Opavsk 272 793 68 Dvorce u Brunt lu CZECH REPUBLIC Telephone 420 554 797 111 Fax 420 554 745 500 E mail prodej dvorce kvs ekodivize cz www kvs ekod...

Отзывы: