Appliance hob-top panel (variants)

 

1)

 The standards panel consists of two parts (Drawing 2):  

     Plate I. – a cast iron range hob with a round removable centre plate located directly under  
     the fire box. This plate is meant for fast cooking 
     Plate II. – a steel hob is located above the oven. This plate maintains a lower temperature  
     and thus can be used for slower cooking, simmering and keeping food warm.  

2)

 The single-piece ground steel finish hob-top panel. 

3)

 The single-piece glass and ceramic panel. 

You should always use pots with flat bases.  
 

 

Drawing 2 

Ignition Flap (Drawing 3) 

Is placed below the range and controlled by means of the lever located at the rear of the range 
frame. It has the following operating modes: 
 
Open position –  Ignition and 

intensive cooking 
throughout the entire range area I.+II. 
(Flap open) 

 
 
 
 
 
 
Closed position – Baking in the oven and  

Cooking on the Plate I. 
(Flap closed) 

 

       Drawing 3 

Following ignition, after the fire has caught, close the ignition flap and operate the appliance with 
the ignition  flap closed. This will  influence  the  flow  of  flue-gas  and  increase  the  efficiency  of  the 
appliance. 
 
 

Содержание 9112-HEU

Страница 1: ...TYPE 9112 HEU 07 2014 TYPE 9112 HEU OPERATION MAINTENANCE MANUAL INSTALLATION MANUAL SOLID FUEL RANGE COOKER WITH HOT WATER HEATER...

Страница 2: ...for contact with foodstuff under all normal conditions or by the stated use of the manufacturer comply with the requirements of Law No 258 2000 Coll the Ministry of Health Decree No 38 2001 Coll and R...

Страница 3: ...ntion to fire safety It is forbidden to use the appliance if it is damaged unfit for its function Any contravention of the operating conditions may cause damage to some parts of the appliance It is re...

Страница 4: ...o the water to the water range 5 5 kW 3 5 kW Efficiency at NHO 75 Average temperature of flue gas at NHO 190 C Mass flow rate of flue gas at NHO 12 g s Minimum chimney draught 12 Pa Height of the work...

Страница 5: ...Storage Drawer 2 Hob Top Plate II 8 Thermometer 3 Oven Door 9 Ash chamber Door 4 Combustion chamber Fire box Door 10 Grate bar 5 Hand Rail 11 Smoke Flap Control 6 Sweeping Door 12 Combustion Air Intak...

Страница 6: ...control of air to the combustion chamber and thus alters the speed of fuel combustion energy output of the appliance The secondary combustion air supply can be controlled by means of a lever on the f...

Страница 7: ...p panel 3 The single piece glass and ceramic panel You should always use pots with flat bases Drawing 2 Ignition Flap Drawing 3 Is placed below the range and controlled by means of the lever located a...

Страница 8: ...utes and perform grating at the same time the combustion performance will improve The appliance output can be controlled by the supply of air under the grate and by the amount and type of fuel When op...

Страница 9: ...rinks and 48 hours for food of solid or pasty consistence The Heat Exchange Unit The range cooker with built in heat exchange unit demands more user attention than a standard cooker or a typical boile...

Страница 10: ...ng that individual parts fit tightly and seal perfectly Outer surfaces cleaning Clean the appliance after cooling Enamelled surfaces should be cleaned with a damp cloth or sponge and then polished to...

Страница 11: ...anufacturer reserves the right to carry out small changes resulting from innovative or technical changes of the product that will have no detrimental affect on the function of the appliance 1 Producti...

Страница 12: ...hrough the hob top it is necessary to remove the blanking cap and to attach the flue branch without the ring and use the delivered blank cover to close the rear outlet A chimney with a sufficient drau...

Страница 13: ...tive baffle plate shall overlap the protected material up to the nearest wall ceiling made of a fireproof material however not less than 300 mm at the upper side and 150 mm at the lateral sides We rec...

Страница 14: ...o use the connection with an open expansion tank in case of some air vaporization from the exchanger If the connection with the expansiomate is used it is necessary to mount a safety valve of 1 8 bar...

Страница 15: ...TYPE 9112 HEU 07 2014 14 Dimensional Sketch of the appliance TYPE 9112 All of dimensions are in mm...

Страница 16: ...TYPE 9112 HEU 07 2014 15 Installation schematic of the range cooker with a heat exchange unit within the interior of a domestic dwelling...

Страница 17: ...TYPE 9112 HEU 07 2014 16 NOTE The valves a pump and other safety accessories are not supplied with the cooker...

Страница 18: ...TYPE 9112 HEU 07 2014 17 Spare parts sketch part 1...

Страница 19: ...TYPE 9112 HEU 07 2014 18 Spare parts sketch part 2...

Страница 20: ...set 014 Ribbon 040 Chamotte lower panel 015 Plug plastic 041 Grate bearing 016 Ribbon 2 042 Rotatable grate 017 Cover strip 043 Grate bar 018 Oven door with frame 044 Frame set 018A Oven door frame 04...

Страница 21: ...TYPE 9112 HEU 07 2014 20...

Страница 22: ...112 HEU 07 2014 Producer KVS EKODIVIZE a s plant Dvorce Opavsk 272 793 68 Dvorce u Brunt lu CZECH REPUBLIC phone 420 554 797 111 fax 420 554 745 500 email prodej dvorce kvs ekodivize cz www kvs ekodiv...

Отзывы: