TracVision R5SL
6
Gyro Replacement Instructions
c.
Secure the new elevation motor to the elevation motor
mounting plate using the two screws you removed in
Step 1d on page 3
.
NOTE:
Be sure to apply a small amount of the supplied Loctite
threadlocker to the threads of the screws.
Figure 10 Elevation Motor Shaft Nut (motor shown unmounted for clarity
purposes)
d.
Extend the elevation motor shaft by rotating it
clockwise, then insert the motor shaft into the
connecting rod (see
Figure 2 on page 2
).
e.
Using an 11/32" open-end wrench, tighten the
elevation motor shaft nut.
f.
Reinstall the radome. Then reconnect power to the
TracVision system.
Nut
Elevation
Motor