![Kvaser Hybrid Pro Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/kvaser/hybrid-pro/hybrid-pro_user-manual_2012921014.webp)
Kvaser Hybrid Pro 2xCAN/LIN User’s Guide
14 (23)
•
When a t program is started using the CANlib API (
kvScriptStart()
).
•
When a t program is started from another t program.
The “on stop” event will be triggered for running t programs during the
corresponding cases:
•
When a t program is stopped using the CANlib API (
kvScriptStop()
).
•
When a t program is stopped from another t program.
4.3
Technical data
In Table 8 you will find the Kvaser Hybrid Pro 2xCAN/LIN’s technical specifications.
CAN/LIN Channels
2 (Individually configurable as CAN or LIN)
CAN Transceivers
TJA1051T/E (Compliant with ISO 11898-2)
CAN Bit Rate
50 kbit/s to 1 Mbit/s
CAN FD Bit Rate
Up to 5 Mbit/s (with correct physical layer implementation)
CAN/LIN Controller
Kvaser CAN/LIN IP in FPGA
LIN Transceivers
TJA1021T/20
LIN Bit Rate
1 - 20 kbit/s
Time stamp resolution
1 µs
CAN Max message rate
20000 msg/s per channel
Error Frame Detection
Yes
Error Frame Generation
Yes
Silent mode
Yes
Kvaser MagiSync
Yes
PC interface
USB 2.0
Power consumption
max 280 mA
Hardware configuration
Done by software (Plug & Play).
Software requirements
Windows 7 or later. (For other operating systems, contact Kvaser sup-
port.)
Dimensions
50 x 170 x 20 mm for body incl. strain relief
Weight
170 g
Operating temperature
−40
◦
C to +85
◦
C
Storage temperature
−40
◦
C to +85
◦
C
Relative humidity
0 % to 85 % (non-condensing.)
Table 8: Technical Specifications.
4.4
CAN/LIN connector
Kvaser Hybrid Pro 2xCAN/LIN devices that use the 9-pin D-SUB connector (see
Figure 5 on Page 15) have the pinning described in Table 9 on Page 15.
Kvaser AB, Mölndal, Sweden — www.kvaser.com