Powering Operations for the 979-2
2-16
KVAL 979-2 Operation/Service Manual
How to Power Down the 979-2
1.
1
2
3
Push the
Stop
Button
on the operator station.
2.
Switch the green
CONTROL TRANSFORMER
switch to the
OFF position.
3.
KVAL also recommends that you turn the disconnect
switch on the electrical cabinet to OFF; this helps reduce
possible damage resulting from power surges from electri-
cal storms.
Emergency Shutdown and Recovery
There are emergency shutdown (E-Stop) switch located at key points
around the machine.
The E-Stop switches are to be used when the machine is out of control
or is about to damage personnel or equipment.
When an E-Stop switch is activated, power to the machine is killed.
The machine responds, in the same way, if you press the STOP button
on the operator's station.