About the 700-DC
KVAL 700-DC Operation/Service Manual
2-4
About the Sill End Controls
Hands Free Buttons to step through the process, hand selection, step Back and step forward con
-
trols are located at the Sill end of the machine. For detailed information about these controls,
“How to Process a Door” on page 2-16.
About the Sill End Controls
The main operating controls are located at the Out-Feed of the machine. Along with the foot
pedal, these control process the door. Below the controls are described. For detailed information
about these controls,
see “How to Process a Door” on page 2-16.
Left Hands Free Button:
Press both Left Hand and
Right Hand simultaneously to
step through processing the
door.
Reset Right:
Resets the machine
to process a Right Hand door
Fire Guns:
Press this button and
the Right Hands Free Button to
fire the staples.
Reset Left:
Resets the machine to
process a Left Hand Door
Right Hands Free Button:
Press both Right Hand and
Left Hand simultaneously to
step through processing the
door.
Press The Right Hand Button
and the Fire button simultane
-
ously to fire the staples.
Press the Right Hand Button
and Reset Right or Reset Left
to set the Door hand
Right Hands Free Button:
Press
both Right Hand and left Hand
simultaneously to clamp the door
header.
Left Hands Free Button:
Press both Left Hand and
Right Hand simultaneously to
clamp the door header.
Содержание 700-DC
Страница 4: ...Kval 700 DC Operation and Service Manual ...
Страница 8: ...700 DC Operation and Service Manual Table of Contents ...
Страница 25: ...Kval Return and Warranty Policy 1 17 KVAL 700 DC Operation Service Manual Page Intentionally Left Blank ...
Страница 50: ...Description of the Six Light Panel KVAL 700 DC Operation Service Manual 2 24 ...
Страница 60: ...Description of Air Input System KVAL 700 DC Operation Service Manual 3 10 ...
Страница 71: ......