ADVR-054 

 

Universal Hybrid Analog-Digital 

Voltage Regulator Operation Manual 

 
 
 
 

 

 

 
 

 

 

Self Excited 5 Amp Analog / Digital Voltage Regulator 

For shunt and auxiliary windings generators 

With over-excitation and lost of sensing protection 

Use with Kutai EP200 Paralleling Module for parallel operation 

Содержание ADVR-054

Страница 1: ...t Qianzhen Dist Kaohsiung City 80664 Taiwan ADVR 054 Universal Hybrid Analog Digital Voltage Regulator Operation Manual Self Excited 5 Amp Analog Digital Voltage Regulator For shunt and auxiliary windings generators With over excitation and lost of sensing protection Use with Kutai EP200 Paralleling Module for parallel operation ...

Страница 2: ...e 170 260 Vac 220 Vac 1 phase 2 wires Max 8 watts 340 520 Vac 440 Vac 1 phase 2 wires 220 440 Vac DIP switch setting Under Frequency Protection Factory Presets Frequency 50 60 Hz DIP switch setting 50 Hz system presets knee point at 45 Hz 60 Hz system presets knee point at 55 Hz Power Input B C Voltage 100 300 Vac 1 phase 2 wires Over Excitation Voltage Protection Frequency 40 60 Hz Set point 78 V...

Страница 3: ...ch ATTENTION 1 Only qualified technicians should install and operate the AVR 2 The voltage regulator may be installed at any suitable location on the generator set dimensions are shown in Figure 1 It is recommended that unit is mounted vertically with the green resistors on the regulator upwards to achieve the best cooling effect 3 All AC voltage sensing readings are average value only Figure 1 Ou...

Страница 4: ...anging loads If the setting is too high the voltage is unstable but if set too low the response is sluggish We recommend using an analog DC voltage meter on F F and adjust STAB for the lowest amount of voltage fluctuation needle movement 3 Last Under Frequency U F adjustment The U F is Factory preset and needs no adjustments put in rare applications Use the U F LED as a guide When this LED is ON t...

Страница 5: ...ADVR 054 Aux winding 1000 Ohm EXT VR G Field R S N T ADVR 054 Figure 5 340 520V sensing connection Figure 6 Auxiliary Winding connection Package include 4 pcs of M4 L25 Round head bolts and 2 pcs of terminal jumpers Use only replacement fuses specified in this user manual Appearance and specifications of products are subject to change for improvement without prior notice Refer to Section 3 for DIP...