background image

MIDI Mode

The Channels Page

10-8

              

The Channels Page

Press the CHANLS soft button to select the CHANLS page, where you can define numerous 
parameters for each MIDI channel independently. Use the CHAN/BANK buttons to select the 
MIDI channel you wish to work on.

The CHANLS page is very useful when you’re doing multi-timbral sequencing, with programs 
assigned to numerous MIDI channels. The CHANLS page lets you set several control 
characteristics for each MIDI channel. This makes it easy to adjust the playback of the sequence 
without editing the sequence itself. For example, you might turn off the Enable parameter for 
one or more channels to mute the tracks on those channels. You could also set the VolLock 
parameter to On, to ignore any MIDI volume messages the K2500 receives on a given MIDI 
channel.

MIDIMode:CHANNELS||||||||||<>Channel:1||

Enable||:

On||||

|||||||||||||||||||||||||

Program|:1|Grand|Piano|||||||PrgLock:Off

Pan|||||:64||||||||||||||||||PanLock:Off

Volume||:127|||||||||||||||||VolLock:Off

OutPair|:Prog|||||||||||||||||||||||||||

OutGai

n

|:Prog

|

||||||

|

||||||

|

||||||

|

|||||

XMIT||

|

RECV||

|

CHANLS

|

PrgChg

|

RsetCh

|

Panic

PARAMETER

RANGE OF VALUES

DEFAULT

ENABLE

Off, On

On

PROGRAM

Program list

Program ID 1

PAN

0 to 127

64 (centered)

VOLUME

0 to 127

127 (maximum)

OUTPUT PAIR

Prog, A (FX), B (DRY), C(DRY), D(DRY)

Prog

OUTPUT GAIN

Prog, –12 to 30 dB in 6 dB increments

Prog

PROGRAM LOCK

Off, On

Off

PAN LOCK

Off, On

Off

VOLUME LOCK

Off, On

Off

Enable

Use this parameter to turn the currently selected channel on or off. When on, the channel will 
receive MIDI information, and the settings of the parameters on the MIDI CHANLS page will 
be in effect. When off, the channel will ignore all MIDI information.

Program

Use this parameter to assign a program to the currently selected channel. The channel will still 
respond to program change commands received via MIDI, unless the PrgLock parameter 
(described below) is set to On.

Pan

This will offset the pan position of the current program as set on the OUTPUT page in the 
Program Editor. A value of 0 is maximum offset to the left, 64 is no offset, and 127 is maximum 
offset to the right. Changing the value of this parameter is like inserting a MIDI pan message. 
MIDI Pan (MIDI 10) messages will change the value of this parameter, unless the PanLock 
Parameter (described below) is set to On.

Содержание K2500

Страница 1: ...ke Mod Wheel messages etc It also affects the responses of other MIDI devices receiving MIDI from the K2500 when the Local Keyboard Channel parameter is set to match the transmission channel of your MIDI controller It s important to remember that many of the settings of the XMIT page are in effect only when a program is selected either in Program mode or in Quick Access mode If a setup is selected...

Страница 2: ...revent the K2500 s MIDI signal from looping back on itself which can cause problems If you deactivate your sequencer s Patch Thru feature set the Control parameter s value to Both and the K2500 will play normally Also you may want to set the value of the LocalKbdCh parameter to None when you have a MIDI loop because you can have problems with doubled notes and MIDI overload You won t have problems...

Страница 3: ... If you have the MIDI In port of another K2500 or K2000 connected to the first one s MIDI Out port the second K2500 or K2000 will respond to every button press on the first K2500 or K2000 just as if you were pressing the buttons of the second one Keep in mind that both devices must be in exactly the same state the same page in the same mode with identical lists of RAM objects when you start Otherw...

Страница 4: ...DI receiving capabilities of the K2500 When set to Omni the K2500 responds to incoming MIDI events on all MIDI channels and plays them on the current channel This is normally used for diagnostic purposes only At a setting of Poly the K2500 will respond only to events that are sent on the same channel as the K2500 s current MIDI channel the one displayed on the top line of the Program mode page In ...

Страница 5: ...entiates between more than one MIDI device of the same model You won t need to change the default setting of 0 unless you have multiple K2500s receiving SysEx messages from a single source In that case make sure each K2500 has a different SysExID Then you can direct SysEx messages to the appropriate K2500 with the SysExID byte that s included with every SysEx message A value of 127 specifies Omni ...

Страница 6: ... the program assigned to channel 5 But if you turn Local Keyboard Channel off by setting it to None then if you send on channel 1 you will hear the program that is assigned to channel 1 even if you are looking at channel 5 Local Keyboard does more than just change the MIDI channel When Local Keyboard Channel is set to None you will notice that the Octav and Octav soft buttons found in Program Setu...

Страница 7: ...k parameter for Channel 1 is on and the K2500 will send a Volume message to its MIDI Out port on channels 1 2 and 3 Bank Select BankSelect allows you to choose between having the K2500 respond to Controller 0 or Controller 32 or both The reason for this is that various manufacturers have chosen one method or the other The four possible values for this parameter are 0 only transmits and responds to...

Страница 8: ...RAMETER RANGE OF VALUES DEFAULT ENABLE Off On On PROGRAM Program list Program ID 1 PAN 0 to 127 64 centered VOLUME 0 to 127 127 maximum OUTPUT PAIR Prog A FX B DRY C DRY D DRY Prog OUTPUT GAIN Prog 12 to 30 dB in 6 dB increments Prog PROGRAM LOCK Off On Off PAN LOCK Off On Off VOLUME LOCK Off On Off Enable Use this parameter to turn the currently selected channel on or off When on the channel will...

Страница 9: ...Editor In this case the channel s output group will change depending on the program assigned to it with the output group being routed on a per layer basis within the program Values of A B C or D fix the output group regardless of the program that s assigned to the channel Output Gain OutGain OutGain will boost or cut the level at the audio outputs for any program assigned to the currently selected...

Страница 10: ...keep track of your programs The K2500 can use several different formats for interpreting Program change commands The values for the program change Type parameters on the XMIT and RECV page determine which format is used and the one you should select depends on your MIDI system If you expect you ll always change programs from your K2500 s front panel you can finish this paragraph and skip the next ...

Страница 11: ... both the Bank Change controller and double program change method but it will always transmit the Bank Change controller When set to Kurzweil the K2500 will receive and transmit only the double program change method Extended Program Changes If you re connected to a MIDI device that can handle the MIDI Controller 0 program change format your flexibility increases considerably We ll discuss first ho...

Страница 12: ...ogram in current bank 1st PCH is ig nored since it s above 109 PCH value 127 PCH value 104 No change in current program 400s bank se lected pending next PCH MC 32 value 0 PCH value 99 Program 99 0s bank 99th program MC 32 value 1 PCH value 42 Program 142 100s bank 42nd program MC 32 value 9 PCH value 0 Program 900 900s bank 0th program MC 32 value 9 None 900s bank selected no change in current pro...

Страница 13: ...e Extended program change format but it goes one step further When receiving the incoming program change commands are interpreted just as they are in the normal Extended format But the resulting program change number instead of selecting a program selects a Quick Access bank entry you must be in Quick Access mode for this to work There are two advantages to using this format First it allows you to...

Страница 14: ...entry within that bank 100 107 Selects QA bank 0n 1n 2n 3n 4n 5n 6n 7n in current memory bank 110 127 Ignored Depending on the QA bank entry you want to select you ll send the K2500 one or two program change commands Sending a single command will let you select from a range of 10 QA banks and select an entry within that bank see the table below To select a different range of QA banks send two prog...

Страница 15: ...ory bank you can enter MC 32 values as high as 7 and PCH values as high as 107 for the first program Change command And you can enter PCH values as high as 59 for the second program change command If the 200s Memory Bank is Currently Selected 1st program change 2nd program change Resulting selection command received command received MC 32 value 0 PCH value 6 QA bank 200 entry 6 MC 32 value 0 PCH v...

Страница 16: ...ess 5 on the alphanumeric pad the K2500 selects for itself whatever program or setup is programmed for that bank and entry The K2500 then sends the following two program change commands to its MIDI Out port MC 32 value 1 followed by PCH value 95 The first program change command is always of the MC 32 type The currently selected memory bank is not included the program change command Quick Access Ba...

Страница 17: ... 84 117 7 101 77 QA 0 127 Finally there s the QA Bank format for use with older MIDI devices Program change commands 0 127 only It works similarly to the other QA formats but the allowable range of values is limited to 0 107 The K2500 expects to receive PCHs of value 0 99 to select a bank and entry or a pair of PCHs the first having a value of 100 107 to select a different 10 bank range When you s...

Страница 18: ...ange the program change number that will be sent When you ve set the channel and the program change number press the Send soft button to send the program change command Or press the Cancel soft button if you don t want to send it You can change the channel and the program number as many times as you want before you press Send You also can use the alphanumeric pad to select a program number directl...

Отзывы: