FXAlg #714: QFlange
Algorithm Reference-85
Fl L/R Phase
The phase angles of the left and right LFOs relative to each other and to the system
tempo clock, if turned on (see Fl Tempo). In all other respects the right and left channels
are symmetric. For example, if one LFO is set to 0
°
and another is set to 180
°
, then when
one LFO delay tap is at its shortest, the other will be at its longest. If the system tempo
clock is on, the LFOs are synchronized to the clock with absolute phase. A phase of 0
°
will put an LFO tap at the center of its range and its lengthening. Using different phase
angles for left and right, the stereo sound Þeld is broken up and a stereo image becomes
difÞcult to spatially locate. The effect is usually described as ÒphaseyÓ. It tends to impart
a greater sense of motion.
Fl StatLvl
The level of the ßanger static delay tap. Negative values polarity-invert the signal.
Setting the tap level to 0% turns off the delay tap.
Fl LFO Lvl
The level of the ßanger LFO modulated delay tap. Negative values polarity-invert the
signal. Setting the tap level to 0% turns off the delay tap.
FlStatDlyC
The nominal length of the ßanger static delay tap from the delay input. The name
suggests the tap is stationary, but it can be connected to a control source such as a data
slider, a ribbon, or a V.A.S.T. function to smoothly vary the delay length. The range for
all delays and excursions is 0 to 230 ms, but for ßanging the range 0 to 5 ms is most
effective.
FlStatDlyF
A Þne adjustment to the ßanger static delay tap length. The resolution is one sample.
Fl Xcurs C
The ßanger LFO excursion controls set how far the LFO modulated delay taps can move
from the center of their ranges. The total range of the LFO sweep is twice the excursion.
If the excursion is set to 0, the LFO does not move and the tap behaves like a simple
delay line set to the minimum delay. The range for all delays and excursions is 0 to 230
ms, but for ßanging the range 0 to 5 ms is most effective. This parameter is a coarse
adjustment for the excursion.
Fl Xcurs F
A Þne adjustment for the ßanger LFO excursions. The resolution is one sample.
Fl Delay C
The minimum delay for the ßanger LFO modulated delay taps. The maximum delay
will be the minimum plus twice the excursion. The range for all delays and excursions is
0 to 230 ms, but for ßanging the range 0 to 5 ms is most effective. This parameter is a
coarse adjustment for the delay.
Fl Delay F
A Þne adjustment to the minimum ßanger delay tap lengths. The resolution is one
sample.