Küppersbusch GKS 644.0 Скачать руководство пользователя страница 12

For internal use only

12

Service Manual GKS 324.0 + GKS 644.0

4. Changing of Components

4.1 Disassembly of the Hob

• To remove the glass surface, lift out the ribbed plates and burner lid.

• Remove the control knobs.

• Unscrew the circumferential fastening screws of the base trough.

• Then lift out the glass surface with the frame towards the top.

• Now all internal technical components are accessible.

4.2 Changing of Components

1. Ignition device

The ignition transformer is fastened on the left-hand side of the base trough by means of adhesi-
ve tape which is supplied with the ignition transformer.

The spark plugs are fastened from the underside of the burner head by means of 1 screw each.
To remove these spark plugs the gas supply line to the burner head must be loosened and the
burner head screwed off from the underside of the appliance. Disassemble the spark plug by lif-
ting the burner head.

The ignition switches are fastened at the gas tap by means of plastic brackets.

2. Thermoelectric safety pilot

The thermodetectors are fastened at the burner head by means of a union nut 13 mm SW and
at the gas tap by means of a screw 8 mm SW. For disassembly undo both screw connections
and remove the thermoelement.

In order to replace the solenoid inserts remove the thermoelement from the gas tap. Undo the
union nut 13 mm SW at the gas tap. Pull solenoid inserts out of the gas tap.

After reassembly carry out a leakage test.

3. Gas taps

In order to change the gas taps separate the ignition switch by force, remove the fastening
bracket of the gas tap by undoing 2 screws and lift the float rail by loosening the screws at the
underside of the appliance. After reassembly carry out a leakage test.

Содержание GKS 644.0

Страница 1: ...GB Glass Ceramic Gas Hobs GKS 324 0 GKS 644 0...

Страница 2: ...Technical Manual H 2 120 59 01 Responsable Kirchmair Tel 0209 401 718 Fax 0209 401 743 Date 26 05 1998 K ppersbusch Vertriebsges mbH Kundendienst Postfach 100 132 45801 Gelsenkirchen...

Страница 3: ...GKS 324 0M 11 4 Changing of Components 12 4 1 Disassembly of the Hob 12 4 2 Changing of Components 12 5 Wiring Plans 13 5 1 GKS 644 0 13 5 2 GKS 324 0 14 6 Conversion to A Different Gas Type Table of...

Страница 4: ...ion 1 2 1 1 Built In Glass Ceramic Gas Hob GKS 644 0 GKS 644 0 M E natural gas in metallic design stainless steel look GKS 644 0 J E natural gas in jet black design black The new built in glass cerami...

Страница 5: ...ssory Features Hardline design Built in glass ceramic gas hob with 2 cooking zones low emission gas burners integrated in the glass ceramic surface 1 high speed cooking zone 1 9 kW 1 standard cooking...

Страница 6: ...or high speed cooking zone 7 Control for left hand top standard cooking zone 1 8 Control for simmering zone 9 Control for right hand bottom standard cooking zone 4 1 Standard cooking zone 2 High speed...

Страница 7: ...covering or the varnish must be processed with heat resistant adhesive 100 C The minimum distance of fume exctractors and wall cupboards above the cooking surface must be 650 mm It is recommended to...

Страница 8: ...nd fasten the loosely attached self adhesive expanded rubber gasket at the underside of the cooking zone frame starting at the rear middle After the assembly the gasket must fit as shown in the drawin...

Страница 9: ...d side of the worktop recess align and fasten The attached fastening brackets are inserted in the front and rear recesses at the underside of the cooking hob and screwed down to the worktop see drawin...

Страница 10: ...For internal use only 10 Service Manual GKS 324 0 GKS 644 0 3 Technical Components Exploded View 3 1 GKS 644 0J GKS 644 0M...

Страница 11: ...For internal use only Service Manual GKS 324 0 GKS 644 0 11 3 2 GKS 324 0J GKS 324 0M...

Страница 12: ...head must be loosened and the burner head screwed off from the underside of the appliance Disassemble the spark plug by lif ting the burner head The ignition switches are fastened at the gas tap by m...

Страница 13: ...For internal use only Service Manual GKS 324 0 GKS 644 0 13 5 Wiring Plans 5 1 GKS 644 0 Trough Ignition device...

Страница 14: ...For internal use only 14 Service Manual GKS 324 0 GKS 644 0 5 2 GKS 324 0 Trough Ignition device...

Страница 15: ...0 Natural gas H E E 20 mbar Pressure pair Natural gas 20 25 mbar Natural gas LL 20 mbar LPG Butane Propane 50 mbar LPG Butane Propane 28 30 mbar Pressure pair Butane Propane 28 30 mbar 37 mbar Factory...

Страница 16: ...tional Testing After the appliance has been completely re assembled a functional testing is to be perfor med Put the appliance into service inaccordance with these operating instructions Check the app...

Страница 17: ...refer to the combustion value and have been calculated with the test gases G20 natural gas H E G25 natural gas LL and G30 LPG The appliance has been checked in accordance with the VDE and DVGW guideli...

Страница 18: ...5 FR I2E 20 1 00 1 65 1 65 3 20 I3 28 30 37 1 00 1 70 1 70 2 75 I3B P 30 1 00 1 70 1 70 2 75 LU I2E 20 1 00 1 65 1 65 3 20 I3B P 30 1 00 1 70 1 70 2 75 AT I2H 20 1 00 1 65 1 65 3 20 I3B P 50 50 0 90 1...

Страница 19: ...an be cleaned in the dishwasher After drying provide them with a thin coating of resin acid free grease or oil in order to avoid corrosion The built in gas hobs manufactured until September 1997 have...