3.2
Installation
3.2.1
Drilling and mounting the supporting plate
1.
The hood can be fastened direct
underneath the wall units with snap-in
holders.
2.
Make an opening underneath the wall
unit as shown on the drawing.
3.
Insert the flange into the top air outlet
opening.
4.
Fasten the cover profile onto the back of
the hood with the screws supplied (2.9 x
12.7).
5.
Open the Comfort Panel with the
corresponding knobs. Then open the
glass steam-extraction canopy.
6.
Remove the light plug.
7.
Move the lever of the fastening pin and
take the panel out of the body of the
hood; at the same time remove the other
end of the panel from the fastening pin.
8.
Remove the grease filters one after the
other by loosening the respective
fastening devices.
9.
Close the glass steam-extraction canopy.
10. Push in the hood until the fasteners on
the side snap in.
11. Open the glass steam-extraction canopy.
12. Permanently fasten the hood from the
bottom using the screws.
13. If necessary align the bottom part as
described below:
•
Loosen the four fastening screws
Vr
and close the glass steam-extraction
canopy again.
•
Move the entire bottom part until it is
in line with the wall unit.
•
Hold the body of the hood, open the
glass steam-extraction canopy and
tighten the fastening screws.