background image

Designer slimline hood

EDIP 9650.0/6650.0

Содержание EDIP 6650.0

Страница 1: ...Designer slimline hood EDIP 9650 0 6650 0...

Страница 2: ...ce Manual H5 85 01 Responsible U Laarmann K PPERSBUSCH HAUSGER TE AG E mail uwe laarmann kueppersbusch de Phone 0209 401 732 Kundendienst Fax 0209 401 743 Postfach 100132 Date 1 06 2006 45801 Gelsenki...

Страница 3: ...5 Accessing the components 11 5 1 The individual units 11 5 2 Test prior to carrying out repairs 12 5 3 Procedure for repairs 12 5 4 Changing the halogen lamps 13 5 5 Replacing the transformer 13 5 6...

Страница 4: ...al current circuit breaker must always be used The earthed conductor resistance must not exceed the resistance specified in the standard It is vital for ensuring the safety of persons and the function...

Страница 5: ...ted and vapours will not be sufficiently removed The cooker hood has been designed to extract vapours generated during the cooking procedure The hood is supplied for extraction air operation If it is...

Страница 6: ...ich are not in operation prior approval must be granted by the master chimney sweep responsible 3 In the case of extraction air operation of the cooker hood and the simultaneous operation of heating s...

Страница 7: ...stening pin and take the panel out of the body of the hood at the same time remove the other end of the panel from the fastening pin 8 Remove the grease filters one after the other by loosening the re...

Страница 8: ...not supplied 2 Remove any charcoal filters which may be in place Connection of the recirculating air model 1 Drill a 150mm hole into the ceiling plate installed above the extraction hood 2 Connect th...

Страница 9: ...I Lighting Switching the lighting on and off T1 0 I Motor on First speed setting Switches the hood off when the button is pressed for approx 1 second T2 Speed setting on Second speed setting T3 Speed...

Страница 10: ...usly been set will have been re activated Example Glass steam extraction canopy pulled out Light ON Motor ON at T2 The functions are all de activated when the glass steam extraction canopy is closed I...

Страница 11: ...microswitch so that the appliance can be switched on Besides serving a design function it also guides steam to the catchment area 3 Control panel unit For switching the lighting and the motor on and...

Страница 12: ...he position of the motor controls Weak suction power Clean the metal filters or replace the charcoal filters in recirculating air hoods Check to ensure that the air hole is not blocked and that it is...

Страница 13: ...f glass and then remove the glass pane 2 Remove the defect lamp and replace it with a new lamp with the same properties simply press the new lamp in 3 Assembly is carried out in reverse order 4 Check...

Страница 14: ...sembling is carried out in reverse order 6 Check the functions 5 6 Replacing the touch controls Should you determine that the control panel circuit board is not functioning replace it as follows 1 Pre...

Страница 15: ...board with one which has the same properties 6 Re assembling is carried out in reverse order 7 Check the functions 5 7 Replacing the electronics unit The circuit board will need to be replaced if the...

Страница 16: ...verse order 6 Check the functions 5 8 Replacing the microswitch Proceed as follows to replace the microswitch 1 Press the two handles on the side to open up the extraction panel for extraction around...

Страница 17: ...ens the wheel and the motor shaft and remove the wheel 4 Remove the four cables on the motor and replace the motor with one which has the same properties 5 Re assembling is carried out in reverse orde...

Страница 18: ...NTENSIVE 250m h 530m h 630m h Noise level MIN setting MAX setting INTENSIVE 46 dB A 61 dB A 65 dB A Exhaust air connection 150mm Pressure 380 PA Voltage frequency 230V 50Hz Appliance dimensions W x D...

Страница 19: ...not function when the T1 button is pressed Fan speed cannot be adjusted when the but tons for the required speed are pressed Intensive setting does not activate when button 4 is pressed The lights hav...

Страница 20: ...20 Service Manual For internal use only 8 Circuit diagram Lamps Microswitch Ring transformer Ribbon cable Control panel...

Отзывы: