INSTALLATION
This canopy hood is designed to be fixed to any rigid vertical surface, over a gas or
electric hotplate and can be used either in the extraction mode (ducted to the outside) or
in the recirculation mode (internal recycling).
Warning
PERSONAL INJURY HAZARD
Because of the weight and size of the rangehood canopy, two or more people are
needed to move and safely install the rangehood canopy. Failure to properly lift
rangehood could result in damage to the product or personal injury.
Components
The hood comprises the following (
fig.1
):
• No.1 canopy
C
complete with controls, lighting and ventilator unit
• No.1 telescopic chimney, comprising:
No.1 upper chimney element
S
No.1 lower chimney element
I
• No.2 directional grills
G
• No.1 recirculation spigot
R
• No.2 additional side recirculation spigots
P1
• No.1 bag containing:
No.2 brackets
2
to fix the chimney, screws, rawl plugs and documents.
• No.1 splashback
B
(optional)
Installation instructions
For easy installation, proceed as follows:
• Fitting the wall brackets and Splashback
• Fixing the canopy
• Electrical connection and working test
• Ducting or Recirculation fitting
• Fitting the telescopic chimney
Fitting the wall brackets and Splashback
Please refer to (
fig.2a-b
):
•
Draw
a vertical line on the wall, from the centre of the cooking appliance up to the ceiling,
using a marking pen. This is to ensure the correct vertical alignment of the various parts.
• Fixing the wall brackets item 2:
a)
Place
one of the brackets
2
against the wall approximately 1 or 2 mm from the ceiling or
from the top limit, aligning its centre (slot) with the vertical line.
b)
Mark
the centres of two keyholes in the bracket on the wall.
c)
Rest
the other bracket
2
against the wall, aligning it with the vertical line, at a distance
X
measured as shown in
fig.2
equal to the height of the upper chimney element
S
supplied
with the hood. The position
X
may vary, according to the various sizes of upper chimney
element available.
d)
Mark
the centres of the keyholes in the bracket on the wall.
Содержание KD 6500.1
Страница 1: ...KD 6500 1 KD 9500 1 GB Instructions Booklet F Mode d emploi...
Страница 2: ...2...
Страница 19: ...G G S I C B R P1 2 1 2 a b...
Страница 20: ...S1 S1 1 1 1 1 1 1 R P1 T G S A18_714_03 R P1 T G S A18_714_03 G 2 S I 2 C 6 4 3 5 8 7...
Страница 21: ...T1 T2 T3 T4 T5 9 10 11 12...
Страница 22: ......
Страница 23: ......