background image

Operation

GB

21

Operation

Instructions for using the hood

The power setting of the hood should be adapted to the occur-
rence of steam during cooking and frying, i.e. for little steam a
low setting should be chosen; the setting should be higher when
a lot of steam occurs.
Please ensure that the hood is switched on at the same time as
the hob so that an air current can build up. This has a positive
effect on the extraction rate. The hood should still run for a while
on completion of cooking so that remaining odours and residual
moisture can be extracted. 

........... Minus button

 (reduce the fan speed)

........... Plus button

 (increase the fan speed)

........... Display

........... Timer button

........... Lamp button 

Switching on the fan and selecting a 
fan setting

The hood is equipped with a fan with several speed settings.
Pressing the 

Minus button

 

 or the 

Plus button

  

will

switch the fan on.
Using the 

Minus key

 

 will immediately select fan setting 4;

using the Plus key 

 will select the first fan setting.

The fan setting is shown by the lighting up of 4 LEDs in the dis-
play.

Switching off the fan

If the 

Plus key

 

 is pressed when the fan setting is at 4, the

hood will be switched off.
If the 

Minus key

 

 is pressed when the fan setting is at 1,

the hood will also be switched off.

LED lamp

Pressing the 

Lamp button

 

 will switch the lamp on and off. 

Timer (automatic switch-off)

The hood is equipped with an automatic switch-off device which
can be used to programme switching off the hood after cooking. 

Procedure

• Switch the hood on and select a fan setting from 1 – 4. The

delayed stop time depends on the fan setting selected:

Fan setting 1  -  20 min.

Fan setting 2  -  15 min.

Fan setting 3  -  10 min.

Fan setting 4  -  5 min.

Press the Timer key

 

 once. The information blinks in

the display. The automatic switch-off device has been activa-
ted.

Please note:

• To deselect the programming mode, press the 

Timer key

 once in acknowledgement or switch the hood off manu-

ally. The display will no longer blink.

Содержание KD 12660.0GE

Страница 1: ...use and installation instructions Instructions d utilisation et avis de montage Gebruiksaanwijzing en montagehandleiding Istruzioni di uso e di montaggio Instrucciones de uso y de montaje Instruções de uso e de montagem KD 9660 0GE KDUM 9660 0GE KD 12660 0GE KDUM 12660 0GE ...

Страница 2: ...ur appliance so that it will provide you with many years of reliable service Should your appliance develop a fault please first consult the section on What to do if trouble occurs You can often rectify minor problems yourself without having to call in a service engi neer Please keep this manual in a safe place and pass it on to new owners for their information and safety Contents Safety instructio...

Страница 3: ...e The air outlets may not be covered during recirculation air operation in order to enable the air to escape freely The hood may not be cleaned with a steam cleaner since safety can no longer be guaranteed due to the steam Do not look into the intensive source of light for too long It is absolutely essential to observe maintenance and cleaning cycles as failure to do so results in a risk of fire a...

Страница 4: ...ance description 1 Chimney top 2 Chimney bottom 3 Canopy 4 Glass canopy safety glass 5 Control elements 6 Metal grease filters both sides 2 filters 7 LED lamp 8 Metal screen 9 Metal grease filter 10 Pressure point for opening see p 23 ...

Страница 5: ...will immediately select fan setting 4 using the Plus key will select the first fan setting The fan setting is shown by the lighting up of 4 LEDs in the dis play Switching off the fan If the Plus key is pressed when the fan setting is at 4 the hood will be switched off If the Minus key is pressed when the fan setting is at 1 the hood will also be switched off LED lamp Pressing the Lamp button will ...

Страница 6: ... To cancel see the section Saturation display The charcoal filter must be replaced sooner when the hood is used more frequently and odours are not sufficiently reduced The metal filter should be cleaned in good time and the charcoal filter replaced in particular in the case of recirculation air operation in order to avoid undesirable deposits of greasy vapours and condensate on kitchen units Besid...

Страница 7: ...een must remain at the top Removing the metal screen The metal screen can be removed to clean it It must hang downwards to remove it the hood is open Caution it could fall onto the hob so please hold it firmly Protect the hob located below the hood with a thick blanket To remove the metal screen hold it and press the bolt on the bearing inwards this will release the metal screen on one side It can...

Страница 8: ...at it can be optimally cleaned An intensive programme at 65 C if possible should be selected in order to fully remove deposits of fat Restore the mains power supply Replacing the charcoal filters recirculation air operation only The charcoal filter is located directly behind the metal grease filter The metal grease filter will need to be removed in order to replace the charcoal filter Put the char...

Страница 9: ... it see previous section Remove the screws with a screw driver Remove the coloured plugs This can be done carefully with your finger nail or a kitchen knife The light covering plastic and the metal screen will come lose right across Caution it could fall onto the hob so please hold it firmly Remove the metal grease filter possibly with the charcoal filter The plug contacts for the LED strip will b...

Страница 10: ...harcoal filter replaced in good time Is the air removed from the kitched replaced with a sufficient supply of fresh air so that no negative pressure develops Are the air outlets blocked During installation was the outlet air duct miscalculated or not properly installed e g diameter too small exhaust air pipe too long or exhaust air duct too angled The hood is suddenly much noisier during operation...

Страница 11: ...ch rooms Nega tive pressure occurs in a closed room as soon as an extraction air system cooker hood is switched on Pressure may only be equalised with an inflow of fresh air from outside and not by means of the household furnace It must be ensured that no car bon monoxide is extracted from the heating source Suitable measures must be taken in order to ensure that there is a sufficient supply of fr...

Страница 12: ...nsitions between pipe sections are fitted tightly and are waterproof This will prevent the used exhaust air from escaping unintentionally Electric connection The hood is fitted with a mains cable and a plug and can be con nected to any shockproof socket supplying 230 volts of alternat ing current 50 Hz which has been installed in accordance with regulations If the mains cable of this appliance is ...

Страница 13: ...ddle above the cross section on the back Use the M5x20 screws supplied to adjust the body of the hood into a horizontal position Install the mounting bracket 1 for the top part of the chimney underneath the ceiling with screws and dowels Install the mounting bracket 2 for the bottom part of the chimney with screws and dowels Make the connection for extraction air see the previous section Switch th...

Страница 14: ...delivery Install the two parts of the chimney that have been put together onto the body of the hood Here the longer bottom chimney part is hung up onto the mount ing bracket 2 Pressing it down a little will engage it properly into the groove of the hood body Pull the top part of the chimney upwards until it reaches the ceiling Fasten the top chimney part with screws 1 Recirculating air mode only 2...

Страница 15: ... mm 650 1000 x 900 x 520 Extraction air connection piece Outer diameter mm 150 Weight approx kg 32 Electrical connection 2 lamps W Motor W 230 V 50Hz 4 5 75 195 Fan nominal output m3 h 755 Hood maximum extraction rate m3 h 257 629 Max noise db A 48 KD 12660 0GE KDUM 12660 0GE Dimensions Height Width Depth mm 650 1000 x 1200 x 520 Extraction air connection piece Outer diameter mm 150 Weight approx ...

Страница 16: ... Teka Küchentechnik GmbH März 2010 ...

Отзывы: