background image

28

INSTALLATION

TECHNICAL INFORMATION 

FOR FITTERS

Installation  and  all  the  regulation,

transformation and maintenance operations

listed in this section must be carried out

exclusively by qualified personnel.

Incorrect installation may cause injury to people

or animals, or damage to items, for which the

manufacturer cannot be held responsible.

Throughout the life of the system, the devices

for the safety and automatic regulation of the

appliances  must  only  be  modified  by  the

manufacturer or the duly authorised supplier.

3) INSERTING THE HOB

After removing the outer and inner packing of the

various mobile parts, ensure that the hob is

undamaged. If you are in any doubt, do not use the

appliance and connect qualified personnel. 

The  packing  elements  (cardboard,  bags,

polystyrene, nails) must not be left within the

reach of children as they are potential sources

of danger.

Make a hole in the worktop to accommodate the

hob, using the measurements indicated in fig. 9,

ensuring that the critical dimensions of the space in

which the appliance must be installed are observed

(see fig. 10).

The appliance must belong to class 3 and is

therefore subject to all the indications of the

standards for such appliances.

The appliance can be installed with just one lateral

wall (to the right or left of the hob), higher than the

hob and positioned at a minimum distance as

described in the tale below.

FIG. 9

FIG. 10

A

B

C

D

E

1F - 2F  (30)

285

485 

57.5  57.5  73 min.

4F  (60) 553  473 

63.5  63.5  73 min.

MEASUREMENTS TO OBSERVE (in mm)

5F(90)       833  475 

62.5       62.5 

73 

min.

Содержание GKS 3720.0 M

Страница 1: ...considered responsible for any damages to people or to things in the event of incorrect installation or improper use of the appliance INSTRUCTIONS AND RECOMMENDATIONS FOR THE USE INSTALLATION AND MAI...

Страница 2: ...l knob 12 Burner no 5 control knob Caution this appliance has been designed for domestic use in domestic environments by members of the general public It must be used by fully aware adults Children sh...

Страница 3: ...and outer flame at the same time LIGHTING AND USING THE DUAL BURNER Stand the pan on the burner before lighting Despite being controlled by a single knob the DUAL burner can be used in two different w...

Страница 4: ...ensure that children are kept at a safe distance Make sure that pan handles are correctly positioned and supervise the cooking of foods in oil and fat as these are highly flammable Do not use sprays...

Страница 5: ...ings free fig 3 and activating the mechanical aeration device suction hood or electric fan fig 4 and fig 5 Intensive and prolonged use of the appliance may require extra aeration such as the opening o...

Страница 6: ...gree of dirt we recommend for light stains a damp sponge is sufficient Tough encrusted dirt is easily eliminated using a scraper fig 6 not supplied with the hob but easy to find in local stores Use th...

Страница 7: ...Ensure that the enamelled covers A B and C fig 7and 7 A are correctly positioned on the burner head The covers are correctly positioned on the head when they are perfectly stable If the opening and cl...

Страница 8: ...doubt do not use the appliance and connect qualified personnel The packing elements cardboard bags polystyrene nails must not be left within the reach of children as they are potential sources of dang...

Страница 9: ...f the strips must match without overlapping Stick the seal to the glass evenly and securely using your fingers to press it into place Position the hob in the hole in the unit and fasten it in place us...

Страница 10: ...aeration 5 ROOM VENTILATION To ensure correct operation of the appliance it is important to ensure that the room where the hot plate is installed has sufficient ventilation as set out in BS 5440 part...

Страница 11: ...ap GAS PRESSURE TEST Some hot plates models have a test point fitted under the control panel to conduct a gas pressure test proceed as follows turn off the gas supply Remove screw in the pressure test...

Страница 12: ...t must be accessible after fitting When the connection is made directly to the electricity main insert an omnipolar switch between the appliance and the power network in a size suited to the load of t...

Страница 13: ...right or left until the burner flame is conveniently regulated to the Minimum Ensure that the flame does not go out when switching quickly from the Maximum position to the Minimum position It is unde...

Страница 14: ...the burners the diameter of the nozzles and the working pressure for the various types of gas ARRANGEMENT OF THE BURNERS GB IE OTHER MARKETS FIG 15 BURNERS TYPE OF GAS WORKING PRESSURE mbar HEAT CAPA...

Страница 15: ...r to guarantee a perfect seal between the body and the ramp Greasing the valves see fig 20 21 If the movement of a valve becomes stiff grease it immediately following the instructions below dismantle...

Страница 16: ...OF HOB TYPE OF POWER CABLE MONOPHASE CAUTION When replacing the power cable the fitter must keep the earth conductor B longer than the phase conductor fig 22 and must also observe the warnings indica...

Страница 17: ...pane 37 mbar G 20 Natural 20 mbar Qn Natural Gas 3 8 kW Qn LPG 276 G30 271 G31 Voltage 230 240 V Frequency 50 60 Hz 4 BURNERS 60 Category II2H3 G 30 Butane 28 30 mbar G 31 Propane 37 mbar G 20 Natural...

Страница 18: ...38 TECHNICAL DATA OF THE APPLIANCE GAS REGULATION...

Страница 19: ...ied personnel This is why we recommend that you always contact the Dealer who sold the appliance or our nearest Assistance Centre specifying the brand the model the serial number and the type of probl...

Отзывы: