EKS USA

Electrical connection

■ 

Observe all guidelines and regulations from your local electric company.

■ 

You should not be able to touch insulated components when operating the 
appliance.

■ 

The power supply should be a 240 volts system, 2-wire with ground, or a 
120/240 volts system, 3-wire with ground.

Electrical diagram
for a 240 volts system,
2-wire with ground:

Electrical diagram
for a 120 / 240 volts system, 
3-wire with ground:

■ 

Be sure to install an appropriate conduit box (not furnished) to connect the 
cook top. Only a professional electrician or certified technician should install 
a conduit-box or replace the connection cable.

■ 

Don’t shorten the conduit to facilitate service! The conduit should be routed 
to permit the removal of the cook top.

■ 

The conduit-box must be protected by a circuit breaker or fuse, having 
amperage as noted in this chapter.

■ 

The conduit-box can be mounted under the countertop below the cooking 
surface or in a side cupboard in the wall. Do not mount it above the cooking 
surface!

Connection

to a conduit-box (not supplied accessory!)

Total rating

EKS 304.1

2.9 kW, fuse current:

15 A

EKS 604.2

7.2 kW, fuse current:

30 A

EKS 804.1

8.4 kW, fuse current:

40 A

Electrical connection

240 V, 60 Hz

Installation

F

When installing stone countertops, the cooking surface can't be fastened 
with clips. See “Special case: Installation in a stone countertop” on page 7.

Cutting the opening space

– First, neatly cut out the countertop opening.

Be sure to use the proper measurements between the opening to the wall 
for the front, back and side!

– Be sure there is an opening of min. 5 mm between the countertop and the 

front panel! (See “Dimensions and distances”.) 

Seal the cut sections

– Seal the cut areas with a water-repellent protection paint.

Checking or replacing the sealing

– Make sure the seal fits well and has no gaps.

With uneven worktops 

(tile, etc.) be sure to remove the sealing strip and 

apply a temperature resistant and elastic sealant. Such sealing compound can 
be purchased as KÜPPERSBUSCH spare part No. 535569.

– Clean the surfaces according to the instructions on the cartridge, apply the 

sealant, and press the appliance into the opening.

– Cut away all excess sealant and then clean the sealed surface immediately 

with water.

Drive in the clips

– Align the clips carefully and use a 

hammer to drive them in.
Refer to the position of the clips on 
page 4 under “Installation dimensions”.

Countertops with more than 
30 mm (1-1/8") thickness:

With countertops with 30 mm 
(1-1/8") thickness, use two 
screws to secure the clips. 
(Screws not included).

Inserting the cooking surface

– Position the cooking surface on 

the left side (1), align it (2) and 
insert the clips (3). 
Be careful not to pinch the 
connecting cable!

[

The cooking surface must rest 
evenly in the opening. If the 
strain of the cooking surface is 
too strong, the appliance can 
crack while heating up.

F

If the cooking surface is not fixed tightly in 
the opening, it’s too big. In this situation, 
screw the clips down with two screws each 
(not supplied) to raise the spring tension.

Connecting the connecting cable to the conduit-box

– Connect the cooking surface to the conduit-box.

■ 

Pull the excess cable out of the installation area.

Содержание EKS 304.1

Страница 1: ...Installation instructions Important Save for the local electrical inspector s use EKS 304 1 604 2 804 2 223818 I31...

Страница 2: ...e will be provided by an authorized technician during normal business hours What Isn t Covered Service by an unauthorized agency will not be reimbursed Likewise the warranty doesn t cover any damage o...

Страница 3: ...e Instead press the appliance out from the bottom of the opening in the countertop or cabinetry Installation conditions Make sure the plastic finish or the veneer of the built in kitchen furniture has...

Страница 4: ...4 EKS USA Installation dimensions...

Страница 5: ...eral cooktops side by side When installing several cooktops side by side please observe the minimum distances between the countertop openings as shown in the drawings Ventilation opening For models EK...

Страница 6: ...s between the opening to the wall for the front back and side Be sure there is an opening of min 5 mm between the countertop and the front panel See Dimensions and distances Seal the cut sections Seal...

Страница 7: ...r materials the cooking surface has to be fixed from the bottom Clips are not needed Unscrew the screws out of the bottom of the cooking surface as seen below Insert the cooking surface into the openi...

Страница 8: ...K PPERSBUSCH 112 N East Street Suite C Tampa Florida 33602 Telephone 813 229 7096 Fax 813 229 0982 Customer Care line 1 800 459 0844 www kuppersbuschusa com K PPERSBUSCH is a brand of Teka USA Inc...

Отзывы: