EKS 304.0

5

Installation depth

F

The model EKS has an installation depth “B”, which means the cooking 
surface can be mounted above an oven, provided you follow the 
installation dimensions below.

Above the oven EEB 6500.0 or EEB 6600.0:

F

* The gap between the countertop and the front panel is not necessary 
for the model EKS 304.1.

Locate the opening for cook top ventilation directly below the countertop. It 
will be less visible there than between the oven and the front panel.

Above the oven EEB 9600.0 or above a shelf:

F

* The gap between the countertop and the front panel is not necessary 
for the model EKS 304.1.

Locate the opening for cook top ventilation directly below the countertop. It 
will be less visible there than between the oven and the front panel.

Several cooktops side by side

When installing several cooktops side by side, please observe the minimum 
distances between the countertop openings as shown in the drawings:

Ventilation opening: For models EKS 604.2 and 
EKS 804.2 only

If there is a KÜPPERSBUSCH built-in oven installed below the cooktop, the 
installation conditions for the oven will provide the cooktop ventilation, too.

If there isn’t an oven installed 
below the cooktop, you must 
install a shelf there. Make 
sure there is no back panel in 
the installation space of the 
cooktop above the shelf. If 
this isn’t possible, cut out an 
opening of 40 - 55 mm (1-9/16" to 2-3/16") in the bottom shelf.

Model

“A”

“B”

“C”

EKS 304.1*

1-1/8 to 2"

3-3/8"

 2-9/16"

30 to 50 mm

85 mm

 65 mm

EKS 604.2

EKS 804.2

1-1/8 to 2"

4-7/16"

 3-5/8"

30 to 50 mm

113 mm

 92 mm 

Model

“A”

“B”

“C”

EKS 304.1*

1-1/8 to 2"

3-3/8"

 3-3/8"

30 to 50 mm

85 mm

 85 mm

EKS 604.2

EKS 804.2

1-1/8 to 2"

4-7/16"

 4-7/16"

30 to 50 mm

113 mm

 113 mm 

Top view

Detail

Appliance

Countertop

Содержание EKS 304.1

Страница 1: ...Installation instructions Important Save for the local electrical inspector s use EKS 304 1 604 2 804 2 223818 I31...

Страница 2: ...e will be provided by an authorized technician during normal business hours What Isn t Covered Service by an unauthorized agency will not be reimbursed Likewise the warranty doesn t cover any damage o...

Страница 3: ...e Instead press the appliance out from the bottom of the opening in the countertop or cabinetry Installation conditions Make sure the plastic finish or the veneer of the built in kitchen furniture has...

Страница 4: ...4 EKS USA Installation dimensions...

Страница 5: ...eral cooktops side by side When installing several cooktops side by side please observe the minimum distances between the countertop openings as shown in the drawings Ventilation opening For models EK...

Страница 6: ...s between the opening to the wall for the front back and side Be sure there is an opening of min 5 mm between the countertop and the front panel See Dimensions and distances Seal the cut sections Seal...

Страница 7: ...r materials the cooking surface has to be fixed from the bottom Clips are not needed Unscrew the screws out of the bottom of the cooking surface as seen below Insert the cooking surface into the openi...

Страница 8: ...K PPERSBUSCH 112 N East Street Suite C Tampa Florida 33602 Telephone 813 229 7096 Fax 813 229 0982 Customer Care line 1 800 459 0844 www kuppersbuschusa com K PPERSBUSCH is a brand of Teka USA Inc...

Отзывы: