Electrical connection
The built-in hob must be connected to the mains supply by a quali-
fied electrician who is authorised to carry out such work!
Both legal wiring regulations and the requirements of your local
electricity supply board must be fully complied with.
When connecting the appliance it must be ensured that there is a de-
vice which makes it possible to disconnect it from the mains at all poles
with a contact opening width of at least 3 mm. Line-protecting switches,
fuses or contactors are suitable cut-out devices.
When connecting and repairing the appliance disconnect it from the
electricity supply with one of these devices.
The appliance must be installed in such a way that it is completely con-
tact-voltage proof.
The earthed conductor lead must be sufficiently long so that, in the
event of failure of the strain relief, it is not subjected to strain until after
the live wires of the connection cable.
Any superfluous cable must be removed from the installation area be-
neath the appliance.
The induction cooking hob is provided at the works with a temperature-
resistant cable with connector box for cooker connection cables.
The connector box is fastened on the kitchen wall behind the fitted cup-
board. If no built-in oven is installed underneath, the connector box can
also be fastened to the furniture under the hob.
When installing the connector box, a minimum distance to the ground of
300 mm is to be observed in accordance with the drawing.
The connector box must not come into contact with hot parts of the app-
liance.
The connector box must not be used as a power distributor for other
appliances.
The mains connection is made in accordance with the connection
diagram on the connector box. The connection may only be made in the
connector box.
The connector box must not be removed.
The attached connection line must be replaced by the Küppersbusch cu-
stomer service in the event of damage.
The end of the green/yellow protective conductor must be stripped more
than the other conductors.
The appliance has to be earthed.
Caution:
Incorrect connection results in the total destruction of the power electronics.
Electrical connection
Permanent connection by means of an oven
connection socket.
Connection diagram
is depicted on the underside of the applian-
ce, suitable for the various types of mains.
Connection data
Permanent connection 400 V 2 N
∼
50 Hz
Electronics
Voltage: 230 V
Electrical connection 6,8 kW
400 V 2 N
∼
safety current 16 A
230 V 1 N
∼
safety current 32 A
230 V 3
∼
safety current 16 A
Connection cable
Use H 05 RR-F or H 07 RN-F.
Cable length as necessary.
Single-phase connection 230 V phase against neutral conductor
Two-phase connection 400 V system with 230 V phase against neu-
tral conductor
Three-phase system 230 V phase against phase
Supply line from
cooker junktion box
The conductor colours may be different. The connection diagram
and the terminal numbers are the decisive factors.
base
Cable to
the hob
20