8
H1-01-08
For internal use only
2.5
Operating time
The temperature of the cooking zones is time-regulated.
The respective cooking zone will be switched on and off in accordance with the following table,
depending on the control setting.
This means that if the setting is 6 the regulator will be switched on for 14 seconds and will then remain
at OFF for 33 seconds. This time hence amounts to 47 seconds. The regulating cycle will then be re-
commenced.
Switch position
1
2
3
4
5
6
7
8
9
Switching on in sec.
1
4
6
9
11
14
21
28
47
Switching off in sec.
46
43
41
38
36
33
26
19
0
Operating time in seconds
0
10
20
30
40
50
1
2
3
4
5
6
7
8
9
C
o
ok
ing s
e
tt
ing
Seconds
ON in secs.
OFF in secs.