21
english
with current regulations.
•
If the electrical connection is done through a plug and this
remains accessible after installation, then it is not necessary
to provide the mentioned separation device.
•
The air must not be discharged into a flue that is used for
exhausting fumes from appliances burning gas or other fuels
(not applicable to appliances that only discharge the air back
into the room).
•
The lower part of the extractor must be located at a minimum
height of 50 cm above the hob for electric cookers and 65 cm
for gas cookers. If the instructions of a gas cooker indicate a
greater distance these must be observed.
•
Before installing the extractor consult the local rules and
regulations in force with respect to the discharge of air and
fumes.
•
When
the extractor is working at the same time as other non-
electrical cooking equipment, the outlet air pressure must not
exceed 4 Pa (4x10
-5
bar).
•
Before connecting the extractor to the mains, check that both
the voltage and the frequency conform to that shown on the
characteristics label located inside the extractor.
•
To achieve optimum performance the length of the outlet hose
should not exceed 4 meters or include more than two 90º
angles (elbows).
•
Although venting to the outside is recommended, activated
carbon filter may be used to allow the gas to be returned to
the kitchen through the outlet pipe.
Cleaning
•
There is a fire risk if cleaning is not carried out in accordance
with the instructions.
Содержание DW9500.0
Страница 2: ...2...
Страница 3: ...3...
Страница 4: ...4...
Страница 5: ...5...
Страница 6: ...6...
Страница 52: ...52...
Страница 53: ...53 3mm LS FI 50cm 65cm 4Pa 4 x 10 5 bar...
Страница 54: ...54 4 2 90 LED...
Страница 55: ...55 Teka 3 5 1 2 3 4 5 1 2 Timer 3 1 99 4 H 2 7 F...
Страница 56: ...56 40 C 3 6 EN IEC 60335 1 EN IEC 60335 2 31 EN IEC 62233...
Страница 58: ...1 2 3 4 5 2012 19 EU WEEE...
Страница 59: ......