16
17
KGS4503
KGS4504
free standing gas
EN
Before operating your hob please make sure that the burner caps are
well positioned. The right placement of the burner caps are shown
below.
Burner lid
Burner
Safety device (Optional)
Electronic Lighting Device (Optional)
USABLE SOUCEPAN DIAMETER
Rapid Burner
Ø 22 - 26 cm
Semi-rapid Burner Ø 18 - 22 cm
Auxiliary Burner
Ø 12 - 18 cm
Gas oven:
The knob frame or the command panel use a flame symbol to indicate
which burner corresponds with which knob.
Control for oven burner:
Push forward and turn the
corresponding knob in a counter-clockwise direction to the max. (+)
symbol. To turn off the burner, turn the corresponding knobs
clockwise until it stops.
Shown on the knob are different
symbols for off as , maximum flame as and minimum flame
as .
Notes:
• When you start to operate oven burners, please do not close the
oven door and wait 3 minutes with it open.
• If your stove has a thermostat, the mentioned control knob should
be positioned to the desired temperature value (optional).
Nozzle change operation for stovetop gas burners:
1.
Start by closing all gas supply to the stove. Use a driver with a
special head to remove and install the nozzle.
2.
Remove the nozzle from burner with a special nozzle driver and
install the new nozzle
3.
Close the nozzle by hand, open the gas valve and check for gas
leakage using soap.
Nozzle change operation for oven burners:
Remove the stove’s back cover and remove the nozzle fixing body
from the burner. Then, remove the nozzle from the injector body with
a special nozzle driver used to change nozzles. After changing it,
close the nozzle hole by hand, open gas valve and check for gas
leakage using soap on the nozzle-body connection surface. Then,
re-install the nozzle body on the burner using screws.
Reduced Flame Adjustment:
In order to adjust your stove to the gas type, carefully adjust for a
reduced flame by turning the middle screw or the one near the gas
valve, as well as nozzle changes, using a small screwdriver.
From LPG to Natural gas From Natural gas to LPG
Rapid
Burner
3 turns counter-
-clockwise
3 turns clockwise
Semi-rapid
Burner
2.5 turns counter-
-clockwise
2.5 turns clockwise
Auxiliary
Burner
2 turns counter-
-clockwise
2 turns clockwise
Oven
Burner
4.5 turns counter-
-clockwise
4.5 turns clockwise