LIGHTING THE BURNERS

To ignite one of the burners, turn the relative knob anticlockwise to the maximum flame setting.

Press and hold the knob until the burner ignites.

After the burner has ignited, keep the knob pressed for about 5 seconds to allow the thermocouple to warm up.
This safety device shuts off the gas if the flame goes out accidentally (draughts, interruption of gas, liquids boiling over, 
etc.).

The control knob must not be pressed for more than 15 seconds. If, after that time has elapsed, the burner does not 

remain lit, wait at least one minute before repeating the operation.

-

The burner might go out when the knob is released. This means that the thermocouple has not warmed up enough.
In this case, repeat the operations described above.

PRATICAL ADVICE FOR USING THE BURNERS

For optimum burner performance, observe the following 

rules:
-

Use pots and pans that fit the burners (see table on the 
right).

-

Only use flat-bottomed pots and pans.

-

Use the correct amount of water for cooking foods and 
keep the pot covered.

2

1

3

1.

Removable grid

2.

4-crown burner

3.

4-crown burner control knob

Symbols

 Tap closed
 Max. flame
 Min. flame

Burner

Pot Ø

4-crown burner

24 to 26 cm 

DIMENSIONS AND DISTANCES TO BE MAINTAINED (mm)

Note: 

Before fitting a hood above the cooktop, please refer to the user manual for the correct distance.

INJECTOR TABLE

CATEGORY 

II

2E+3+

ELECTRIC SUPPLY: 230 V ~ 50 Hz

Type of gas used

Type of 
burner

Injector 
marking 

Nominal 
heating 
capacity
(kW)

Nominal 
consumption

Reduced heating 

capacity

(kW)

 Gas pressure

(mbar)

BE

FR

min.

nom.

max.

NATURAL GAS
(Methane)

G20

4-crown

139

3,50

333 l/h

1,95

1,55

17

20

25

NATURAL GAS 
(Methane)

G25

4-crown

139

3,50

388 l/h

1,55

20

25

30

LIQUEFIED 
PETROLEUM GAS
(Butane)

G30

4-crown

90

3,20

233 g/h

1,55

20

28-30

35

LIQUEFIED 
PETROLEUM GAS
(Propane)

G31

4-crown

90

3,20

229 g/h

1,55

25

37

45

Type of gas used

Model configuration 1 
BURNER

Nominal heating capacity
(kW)

Total nominal 
consumption

Air necessary (m

3

) or the 

combustion of 1 m

3

 of gas

G20 20 mbar

4-crown

3,50

333 l/h

9,52

G25 25 mbar

4-crown

3,50

388 l/h

8,187

G30 28-30 mbar

4-crown

3,20

233 g/h

30,94

G31 37 mbar

4-crown

3,20

229 g/h

23,80

 AKT 351

PRODUCT DESCRIPTION SHEET

EN

To get full satisfaction from the hob, please read these instructions carefully and keep them for future consultation.

FR

Содержание AKT 351

Страница 1: ...grid 2 4 crown burner 3 4 crown burner control knob Symbols Tap closed Max flame Min flame Burner Pot Ø 4 crown burner 24 to 26 cm DIMENSIONS AND DISTANCES TO BE MAINTAINED mm Note Before fitting a hood above the cooktop please refer to the user manual for the correct distance INJECTOR TABLE CATEGORY II2E 3 ELECTRIC SUPPLY 230 V 50 Hz Type of gas used Type of burner Injector marking Nominal heatin...

Страница 2: ...een designed constructed and marketed in compliance with safety requirements of EEC Gas Directive 90 396 safety objectives of the Low Voltage Directive 2006 95 CE which replaces 73 23 CEE and subsequent amendments protection requirements of EEC EMC Directive 89 336 requirements of EEC Directive 93 68 This hob is suitable for contact with foodstuffs and complies with EEC CE Regulation n 1935 2004 N...

Страница 3: ... a qualified electrician Earth yellow green L N 2 3 1 ADJUSTMENT TO DIFFERENT TYPES OF GAS If the appliance is intended to operate with a different gas from the gas type stated on the rating plate and orange sticker applied on the top of the hob change the injectors Remove the orange sticker and keep it with the instructions booklet Use pressure regulators suitable for the gas pressure indicated i...

Страница 4: ...ntly and if necessary clean them with a damp cloth Any baked on food should be removed with a toothpick or needle Note to avoid damaging the electric ignition device do not use it when the burners are not in their housing TROUBLESHOOTING GUIDE The hob may not work or work incorrectly Before calling the After Sales Service refer to the Troubleshooting Guide to determine the problem 1 The burner fai...

Отзывы: