background image

INSTALLATION

GAS CONNECTION

The gas supply system must comply with local regulations.

You can find specific local regulations for some countries in the paragraph “Reference to Local Regulations”. If no 
information concerning your Country is given, please ask details to your Installer.

The connection of the hob to the gas pipe network or gas cylinder must be made by means of a rigid copper or steel 
pipe with fittings complying with local regulations, or by means of a continuous-surface stainless steel hose complying 
with local regulations. The maximum length of the hose is 2 linear metres.

Before connecting the tube to the elbow fitting (A), interpose the 
washer (B) supplied, in compliance with EN 549.

Attention: if a stainless steel hose is used, it must be installed so as not to touch any mobile part of the furniture. It must pass 
through an area where there are no obstructions and where it is possible to inspect it on all its length.

After connection to the gas supply, check for leaks with soapy water.

ELECTRICAL CONNECTION

The electrical connections must comply with local regulations.

The data relevant to the voltage and power absorption are indicated on the rating plate.

The earthing of this appliance is compulsory by law.

The manufacturer cannot be held responsible for any injury to persons or animals or damage to property arising from 

failure to comply with these requirements.

When the hob is installed, provide a single-pole circuit breaker with a contact separation of at least 3 mm.

If necessary, the electrical power cable must be replaced exclusively with a power cable having identical characteristics 

to the original supplied by the manufacturer (type H05V2V2-F T90°C or H05RR-F). 
This operation must be performed by a qualified electrician.

Earth
(yellow/green)

L

N

2

3

1

ADJUSTMENT TO DIFFERENT TYPES OF GAS

If the appliance is intended to operate with a different gas from the gas type stated on the rating plate and orange sticker 
applied on the top of the hob, change the injectors.
Remove the orange sticker and keep it with the instructions booklet.
Use pressure regulators suitable for the gas pressure indicated in the Product Description Sheet.

The gas nozzles must be changed by After Sales Service or a qualified technician.

Nozzles not supplied with the appliance must be ordered from After Sales Service.

Adjust the minimum setting of the taps.

Note: when liquid petroleum gas is used (G30/G31), the minimum gas setting screw must be tightened as far as it will go.
Should you experience difficulty in turning the burners knobs, please contact the After Sales Service for the replacement of 
the burner tap if found to be faulty.

REPLACING THE INJECTORS 

(see the injector table in the Product Description Sheet)

Remove  grids  (A)

Extract burners (B)

Using a socket spanner of the appropriate size unscrew the injector (C) 

Replace it with the injector suitable for the new type of gas.

Before installing the hob, remember to affix the gas calibration plate 
supplied with the injectors in such a way that it covers the existing 
information relating to gas calibration.

ADJUSTING MINIMUM GAS SETTING OF TAPS

To ensure that the minimum setting is correctly adjusted, 
remove the knob and proceed as follows:

tighten the screw to reduce the height of the flame (-)

loosen the screw to increase the height of the flame (+)

The adjustment must be performed with the tap in minimum 
gas setting position (small flame) 

.

The primary air of the burners does not need to be 

adjusted.

At this stage, light up the burners and turn the knobs 

from max position 

 to minimum position 

 to 

check flame stability.

Upon completion of adjustment, reseal using sealing wax or 
an equivalent material.

Содержание AKT 351

Страница 1: ...grid 2 4 crown burner 3 4 crown burner control knob Symbols Tap closed Max flame Min flame Burner Pot Ø 4 crown burner 24 to 26 cm DIMENSIONS AND DISTANCES TO BE MAINTAINED mm Note Before fitting a hood above the cooktop please refer to the user manual for the correct distance INJECTOR TABLE CATEGORY II2E 3 ELECTRIC SUPPLY 230 V 50 Hz Type of gas used Type of burner Injector marking Nominal heatin...

Страница 2: ...een designed constructed and marketed in compliance with safety requirements of EEC Gas Directive 90 396 safety objectives of the Low Voltage Directive 2006 95 CE which replaces 73 23 CEE and subsequent amendments protection requirements of EEC EMC Directive 89 336 requirements of EEC Directive 93 68 This hob is suitable for contact with foodstuffs and complies with EEC CE Regulation n 1935 2004 N...

Страница 3: ... a qualified electrician Earth yellow green L N 2 3 1 ADJUSTMENT TO DIFFERENT TYPES OF GAS If the appliance is intended to operate with a different gas from the gas type stated on the rating plate and orange sticker applied on the top of the hob change the injectors Remove the orange sticker and keep it with the instructions booklet Use pressure regulators suitable for the gas pressure indicated i...

Страница 4: ...ntly and if necessary clean them with a damp cloth Any baked on food should be removed with a toothpick or needle Note to avoid damaging the electric ignition device do not use it when the burners are not in their housing TROUBLESHOOTING GUIDE The hob may not work or work incorrectly Before calling the After Sales Service refer to the Troubleshooting Guide to determine the problem 1 The burner fai...

Отзывы: