Страница 3: ...prevent damage to property and personal injuries 6 Limitation of Liability 7 Introduction 8 Scope of delivery 8 Areas of use 8 Technical data 9 General data 9 Operation 10 Installation 10 Operation wi...

Страница 4: ...KUNBUS GmbH 4 KUNBUS Ethernet Test Access Point TAP 2100...

Страница 5: ...Measuring and analyzing electrical functions and systems Safety and health at work Assembly and connection of electrical equipment Locally applicable rules and regulations for occupational safety 1 2...

Страница 6: ...ion Only use the TAP 2110 with the supply voltage of 24V DC 5 Using other voltages result in damages or faults Caution Only use the the specified signaling voltage Operation with a signaling voltage o...

Страница 7: ...tion of Liability Warranty and liability claims will lapse if the product has been used incorrectly damage is due to non observance of the operating manual damage is caused by inadequately qualified p...

Страница 8: ...ernet interface Network monitors read and analyze the tapped packet data such as the freely available Wireshark 2 1 Scope of delivery Storage case TAP 2100 Plastic cover Cable for power supply Euro Ad...

Страница 9: ...lex Zero delay 0 s Resolution time stamp 1 ns Diagnostics 3 LEDs Unfiltered forwarding of CRC errors 2 4 General data Supply voltage 24 V DC 20 or 230 V AC plug power supply Weight about 150 g Dimensi...

Страница 10: ...Connect the TAP 2100 with the RJ45 cable to a Gigabyte Ethernet interface of the PC If the connection between PC and TAP is successful the X0 link LED lights up 6 Plug the line to be tested into the...

Страница 11: ...s provided that can easily be understood from the user side This way there is an opportunity to examine individually captured data packets or to sort by specific contents In addition to extracting for...

Страница 12: ...reshark dialog can be accessed via the menu selection Capture Interfaces The dialog in turn shows with all the corresponding IP addresses the respectively recognized network interfaces Furthermore it...

Страница 13: ...nder columns Enter for example tap port as the field name As soon as tap has been entered all possible values are displayed A description is provided below With Add a column can be added Using the mou...

Страница 14: ...at both devices switch over to MDIX and the display of A B is swapped The same applies to C D CRC Error The received packet has a faulty test total Alignment Error The packet is faulty Timestamp The p...

Страница 15: ...ets If a packet is already more than 1480 bytes long the packet on the output port X0 will exceed the maximal allowed length of the Ethernet standard and the packet will be discarded by the network ad...