Kuma Stoves K-180 Alpine LE Скачать руководство пользователя страница 3

 

SECTION 1 - WARNINGS 

 

 

 

WARNING

 

 

If this stove is not properly installed, a house fire can occur.  For your protection, follow the installation 

instructions provided.  We recommend contacting local building or fire officials regarding restrictions and 

installation inspection requirements in your area.  

We also recommend that your Kuma stove be installed 

by a properly trained and licensed installer, preferably an NFI (National Fireplace Institute) expert. 

 

DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVICING ANOTHER APPLIANCE.

 

 

Do not burn garbage or flammable fluids such as gasoline, naptha or engine oil

.  Do not use charcoal 

lighter fluid or similar liquids to start or “freshen up” a fire in this heater.  Keep all such fluids well away from 

the heater while in use.  Storing these fluids near a stove could cause a fire. 

 

DO NOT CONNECT TO ANY AIR DISTRIBUTION OR DUCT SYSTEM. 

 

DO NOT OVERFIRE.  

If any part of the stove or chimney glows, the stove is in an over fire condition.  If this 

happens, shut the air control off immediately.   Over firing can cause damage.

 

 

WARNING: DO NOT INSTALL IN A SLEEPING ROOM. 

 

An improperly drafting stove can cause smoke and carbon monoxide to enter the home. Smoke detectors 

and carbon monoxide monitors are recommended to be installed in the same room as this heater. 

 

CAUTION:

 

THE STRUCTURAL INTEGRITY OF THE FLOOR, WALLS,  ROOF/CEILING, AND VAPOR 

BARRIERS MUST BE MAINTAINED. 

 

DO NOT USE SINGLE WALL PIPE OR CONNECTOR PIPE FOR ANY CHIMNEY APPLICATION, EXTERIOR 

OR THROUGH THE WALL OR CEILING.

  Single wall pipe may only be used as a connection between the 

stove and an approved masonry or stainless steel chimney.  

Single wall pipe may not be used as a 

connector in mobile homes. 

 

When installing into an existing masonry or metal chimney, examine the chimney system carefully.  If you 

have any questions, seek professional advice.  We recommend having existing chimneys cleaned and 

inspected by a qualified professional prior to the installation of your new stove.

 

 

NOTE ALL MINIMUM CLEARANCE REQUIREMENTS TO COMBUSTIBLES.

  Installation must comply with 

minimum clearances as listed in this manual.  

Clearances may only be reduced by means approved by the 

regulatory authority. 

 

Do not operate this stove with the door in an open position, except for cracking open during start-up.  

Continued operation with the door open can cause overheating of the unit, and expose embers to nearby 

combustibles.

 

 

Do not operate with broken glass.  Do not abuse glass such as striking or slamming the door. 

 

This stove must be connected to a minimum 6” diameter listed chimney that complies with U.L. type 103HT 

factory built chimney or a code approved masonry chimney.  When installing into masonry chimneys, a U.L. 

1777 approved liner must be installed.

 

 

When connecting single wall or double wall connector pipe to the stove and chimney, use 3 screws per pipe 

joint including 3 screws securing the pipe to the stove.  Depending on the type of double wall pipe you are 

using, it may also be necessary to fasten it at the chimney.  

 

 

Use only approved components for Chimney and Connector.  Field fabricated or “makeshift” components are 

not allowed and can cause a fire.

 

 

DO NOT USE THIS STOVE WITHOUT THE BAFFLE BOARDS AND CERAMIC INSULATION PACKAGED 

WITH YOUR STOVE.

 

 

When connecting this stove to a masonry chimney, make sure you observe all applicable clearances including 

walls, ceilings and other combustible material.  A masonry chimney must be minimum 6” diameter and 

constructed with a liner according to NFPA code 211.  If you have any questions about the condition or the 

code compliance of your masonry chimney, please speak with a qualified professional.   

 

HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY.  CONTACT MAY 

CAUSE SKIN BURNS. 

Содержание K-180 Alpine LE

Страница 1: ...and listed by OMNI Test Laboratories Inc Portland OR USA Emissions tested to ASTM 3053 2017 Report 0123WM011E Safety tested to UL 1482 2011 R2015 Report 0123WN011S INSTALLATION AND OPERATING INSTRUCT...

Страница 2: ...ue Please visit https www kumastoves com content page EPA for a detailed explanation of stove efficiencies Particulate emissions are 0 72 grams per hour and average CO emissions are 0 10 grams per min...

Страница 3: ...imney system carefully If you have any questions seek professional advice We recommend having existing chimneys cleaned and inspected by a qualified professional prior to the installation of your new...

Страница 4: ...SECTION 2 SPECIFICATIONS CERTIFICATION TAG...

Страница 5: ...K 180 Rev 190829 ALPINE DIMENSIONAL DRAWINGS All dimensions are in inches...

Страница 6: ...side wall 7 5 K1 Insert to wood trim Trim must be no thicker than 3 4 8 5 K2 Insert to wood trim Trim must be no thicker than 7 5 MANTEL CLEARANCE Your mantel can be 12 deep or less A 12 mantel must...

Страница 7: ...uired It is highly recommended that this insert is installed by a qualified professional certified by the National Fireplace Institute The structural integrity of the floor walls and ceiling roof must...

Страница 8: ...NTS A properly installed and maintained venting system is critical to the safe operation of your wood insert This insert may be connected with a liner to a masonry fireplace that meets the standards o...

Страница 9: ...he 2100 flue gas temperature test will receive the designation of a 103HT chimney system HT stands for High Temperature and virtually all modern wood stoves will require this type of chimney UL 1777 C...

Страница 10: ...ecessary airflow around the chimney do not block this airflow The Dura Vent brand has developed a kit 6DFPRO 25KFB specifically for re lining factory built fireplaces for use with wood inserts The pro...

Страница 11: ...OR MANUFACTURED MOBILE HOMES In mobile homes only install into a UL 127 factory built fireplace that has been approved for use in mobile homes Do not install into a masonry fireplace in a mobile home...

Страница 12: ...e meter to determine the moisture content of the wood The recommended wood length for this heater is 16 This heater is designed to burn natural wood only Higher efficiencies and lower emissions genera...

Страница 13: ...use the appliance to leak smoke and carbon monoxide into the room through appliance and chimney connector joints Factors that reduce draft are Too much draft may cause excessive temperatures in the ap...

Страница 14: ...ition helps to quickly heat the chimney and the catalyst during start up by allowing some heat to bypass the catalyst This position also allows you to reload the stove while preventing smoke from comi...

Страница 15: ...is perfectly normal b There is a caution symbol on the probe warning you that you may be exceeding the recommended operating temperature of the catalyst 1300 F It is fine to go above the recommended o...

Страница 16: ...larger pieces Add wood then shut the door 3 As soon as the catalytic thermometer is in or near the active range close the bypass control to the Run Position engaging the combustor 4 Leave the air cont...

Страница 17: ...Troubleshooting section of this owner s manual 2 This hybrid heater is equipped with a temperature probe to monitor catalyst operation Properly functioning combustors typically maintain temperatures...

Страница 18: ...ght fitting lid and keep away from the house NEVER EMPTY ASHES INTO A COMBUSTIBLE CONTAINER SUCH AS A PLASTIC BUCKET OR PAPER BAG NEVER LEAVE ASHES NEAR THE HOUSE OR GARAGE CHIMNEY INSPECTION AND CLEA...

Страница 19: ...he stove If your burn tubes are not physically degraded falling apart crushed or excessively warped then they are functioning and will not need replacement To remove a burn tube un bolt the tube using...

Страница 20: ...fle and is designed to keep heat in the stove and increase efficiency If the insulation is in place it can be left alone If the insulation becomes torn during cleaning simply lay it back together tigh...

Страница 21: ...MAINTENANCE DIAGRAMS PARTS LIST...

Страница 22: ...tic flame guard stainless steel Fits All models 8 KR CT 01 Catalytic combustor metal alloy Includes Gasket KR GK 01 Fits All models 9 KR BT 181 Baffle burn tube front or middle Fits ASP TAM ABR ALP 10...

Страница 23: ...ey reduces the effective area of the chimney by about 20 Pay close attention to the chimney cap especially if it has a screen Screened chimney caps can become blocked enough to restrict flow in just a...

Страница 24: ...dling to build up the heat only put large chunks of wood on a very hot and active bed of coals If there are large chunks of charred wood left after the fire has gone out the coal bed was not hot enoug...

Страница 25: ...ze repair of any defective part at its sole discretion This warranty is not transferrable and covers the original owner of the product from the time of purchase All parts that have been replaced under...

Отзывы: