SECTION 1 - WARNINGS
WARNING
If this stove is not properly installed, a house fire can occur. For your protection, follow the installation
instructions provided. We recommend contacting local building or fire officials regarding restrictions and
installation inspection requirements in your area.
We also recommend that your Kuma stove be installed
by a properly trained and licensed installer, preferably an NFI (National Fireplace Institute) expert.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVICING ANOTHER APPLIANCE.
Do not burn garbage or flammable fluids such as gasoline, naptha or engine oil
. Do not use charcoal
lighter fluid or similar liquids to start or “freshen up” a fire in this heater. Keep all such fluids well away from
the heater while in use. Storing these fluids near a stove could cause a fire.
DO NOT CONNECT TO ANY AIR DISTRIBUTION OR DUCT SYSTEM.
DO NOT OVERFIRE.
If any part of the stove or chimney glows, the stove is in an over fire condition. If this
happens, shut the air control off immediately. Over firing can cause damage.
WARNING: DO NOT INSTALL IN A SLEEPING ROOM.
An improperly drafting stove can cause smoke and carbon monoxide to enter the home. Smoke detectors
and carbon monoxide monitors are recommended to be installed in the same room as this heater.
CAUTION:
THE STRUCTURAL INTEGRITY OF THE FLOOR, WALLS, ROOF/CEILING, AND VAPOR
BARRIERS MUST BE MAINTAINED.
DO NOT USE SINGLE WALL PIPE OR CONNECTOR PIPE FOR ANY CHIMNEY APPLICATION, EXTERIOR
OR THROUGH THE WALL OR CEILING.
Single wall pipe may only be used as a connection between the
stove and an approved masonry or stainless steel chimney.
Single wall pipe may not be used as a
connector in mobile homes.
When installing into an existing masonry or metal chimney, examine the chimney system carefully. If you
have any questions, seek professional advice. We recommend having existing chimneys cleaned and
inspected by a qualified professional prior to the installation of your new stove.
NOTE ALL MINIMUM CLEARANCE REQUIREMENTS TO COMBUSTIBLES.
Installation must comply with
minimum clearances as listed in this manual.
Clearances may only be reduced by means approved by the
regulatory authority.
Do not operate this stove with the door in an open position, except for cracking open during start-up.
Continued operation with the door open can cause overheating of the unit, and expose embers to nearby
combustibles.
Do not operate with broken glass. Do not abuse glass such as striking or slamming the door.
This stove must be connected to a minimum 6” diameter listed chimney that complies with U.L. type 103HT
factory built chimney or a code approved masonry chimney. When installing into masonry chimneys, a U.L.
1777 approved liner must be installed.
When connecting single wall or double wall connector pipe to the stove and chimney, use 3 screws per pipe
joint including 3 screws securing the pipe to the stove. Depending on the type of double wall pipe you are
using, it may also be necessary to fasten it at the chimney.
Use only approved components for Chimney and Connector. Field fabricated or “makeshift” components are
not allowed and can cause a fire.
DO NOT USE THIS STOVE WITHOUT THE BAFFLE BOARDS AND CERAMIC INSULATION PACKAGED
WITH YOUR STOVE.
When connecting this stove to a masonry chimney, make sure you observe all applicable clearances including
walls, ceilings and other combustible material. A masonry chimney must be minimum 6” diameter and
constructed with a liner according to NFPA code 211. If you have any questions about the condition or the
code compliance of your masonry chimney, please speak with a qualified professional.
HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY
CAUSE SKIN BURNS.