Kuma Stoves K-180 Alpine LE Скачать руководство пользователя страница 1

 

 

 

Model # K-180: 

 

Alpine LE 

 
 
 

 

 

Tested and listed by OMNI-Test 
Laboratories Inc. 
Portland OR, USA 
 
Emissions tested to: ASTM 3053-2017 
Report# 0123WM011E 

Safety tested to UL 1482-2011 (R2015) 
Report # 0123WN011S

INSTALLATION AND OPERATING INSTRUCTIONS 

SAVE THESE INSTRUCTIONS

Содержание K-180 Alpine LE

Страница 1: ...and listed by OMNI Test Laboratories Inc Portland OR USA Emissions tested to ASTM 3053 2017 Report 0123WM011E Safety tested to UL 1482 2011 R2015 Report 0123WN011S INSTALLATION AND OPERATING INSTRUCT...

Страница 2: ...ue Please visit https www kumastoves com content page EPA for a detailed explanation of stove efficiencies Particulate emissions are 0 72 grams per hour and average CO emissions are 0 10 grams per min...

Страница 3: ...imney system carefully If you have any questions seek professional advice We recommend having existing chimneys cleaned and inspected by a qualified professional prior to the installation of your new...

Страница 4: ...SECTION 2 SPECIFICATIONS CERTIFICATION TAG...

Страница 5: ...K 180 Rev 190829 ALPINE DIMENSIONAL DRAWINGS All dimensions are in inches...

Страница 6: ...side wall 7 5 K1 Insert to wood trim Trim must be no thicker than 3 4 8 5 K2 Insert to wood trim Trim must be no thicker than 7 5 MANTEL CLEARANCE Your mantel can be 12 deep or less A 12 mantel must...

Страница 7: ...uired It is highly recommended that this insert is installed by a qualified professional certified by the National Fireplace Institute The structural integrity of the floor walls and ceiling roof must...

Страница 8: ...NTS A properly installed and maintained venting system is critical to the safe operation of your wood insert This insert may be connected with a liner to a masonry fireplace that meets the standards o...

Страница 9: ...he 2100 flue gas temperature test will receive the designation of a 103HT chimney system HT stands for High Temperature and virtually all modern wood stoves will require this type of chimney UL 1777 C...

Страница 10: ...ecessary airflow around the chimney do not block this airflow The Dura Vent brand has developed a kit 6DFPRO 25KFB specifically for re lining factory built fireplaces for use with wood inserts The pro...

Страница 11: ...OR MANUFACTURED MOBILE HOMES In mobile homes only install into a UL 127 factory built fireplace that has been approved for use in mobile homes Do not install into a masonry fireplace in a mobile home...

Страница 12: ...e meter to determine the moisture content of the wood The recommended wood length for this heater is 16 This heater is designed to burn natural wood only Higher efficiencies and lower emissions genera...

Страница 13: ...use the appliance to leak smoke and carbon monoxide into the room through appliance and chimney connector joints Factors that reduce draft are Too much draft may cause excessive temperatures in the ap...

Страница 14: ...ition helps to quickly heat the chimney and the catalyst during start up by allowing some heat to bypass the catalyst This position also allows you to reload the stove while preventing smoke from comi...

Страница 15: ...is perfectly normal b There is a caution symbol on the probe warning you that you may be exceeding the recommended operating temperature of the catalyst 1300 F It is fine to go above the recommended o...

Страница 16: ...larger pieces Add wood then shut the door 3 As soon as the catalytic thermometer is in or near the active range close the bypass control to the Run Position engaging the combustor 4 Leave the air cont...

Страница 17: ...Troubleshooting section of this owner s manual 2 This hybrid heater is equipped with a temperature probe to monitor catalyst operation Properly functioning combustors typically maintain temperatures...

Страница 18: ...ght fitting lid and keep away from the house NEVER EMPTY ASHES INTO A COMBUSTIBLE CONTAINER SUCH AS A PLASTIC BUCKET OR PAPER BAG NEVER LEAVE ASHES NEAR THE HOUSE OR GARAGE CHIMNEY INSPECTION AND CLEA...

Страница 19: ...he stove If your burn tubes are not physically degraded falling apart crushed or excessively warped then they are functioning and will not need replacement To remove a burn tube un bolt the tube using...

Страница 20: ...fle and is designed to keep heat in the stove and increase efficiency If the insulation is in place it can be left alone If the insulation becomes torn during cleaning simply lay it back together tigh...

Страница 21: ...MAINTENANCE DIAGRAMS PARTS LIST...

Страница 22: ...tic flame guard stainless steel Fits All models 8 KR CT 01 Catalytic combustor metal alloy Includes Gasket KR GK 01 Fits All models 9 KR BT 181 Baffle burn tube front or middle Fits ASP TAM ABR ALP 10...

Страница 23: ...ey reduces the effective area of the chimney by about 20 Pay close attention to the chimney cap especially if it has a screen Screened chimney caps can become blocked enough to restrict flow in just a...

Страница 24: ...dling to build up the heat only put large chunks of wood on a very hot and active bed of coals If there are large chunks of charred wood left after the fire has gone out the coal bed was not hot enoug...

Страница 25: ...ze repair of any defective part at its sole discretion This warranty is not transferrable and covers the original owner of the product from the time of purchase All parts that have been replaced under...