![Kuka KR C2 Скачать руководство пользователя страница 60](http://html.mh-extra.com/html/kuka/kr-c2/kr-c2_operating-handbook_2009633060.webp)
Machine Data
60 of 91
Maschinendaten 12.0400 en
2.1.122 $FOL_ERR_MA[ ]
Factor for following error monitoring on the DSE
Data type
real
min
Value
20.0
Unit
[ ]
Value
max 20.0
Assignment
[1] axis 1 ... [6] axis 6
[7] external axis 1 ... [12] external axis 6
The definition of the monitoring window for following error monitoring refers to $IN_POS_MA
* $FOL_ERR_MA
If the value is exceeded, the error message “Regulator limit exceeded Ax” is generated and
maximum braking is triggered.
This entry is fixed.
Default value = 20.0
2.1.123 $VEL_ENC_CO
Command speed threshold for encoder monitoring
Data type
int
min
Value
----
Unit
----
Value
max ----
Assignment
----
This machine datum is used exclusively for KUKA--internal development purposes.
2.1.124 $COM_VAL_MI[ ]
Command speed limitation
Data type
real
min
Value
150.0
Unit
%
Value
max 150.0
Assignment
[1] axis 1 ... [6] axis 6
[7] external axis 1 ... [12] external axis 6
Limitation of axis command speed.
The command speed value is limited to the value specified in $COM_VAL_MI.
This entry is fixed.
Default value = 150.0