![Kuka KR C2 Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/kuka/kr-c2/kr-c2_operating-handbook_2009633022.webp)
Machine Data
22 of 91
Maschinendaten 12.0400 en
This variable specifies the control loop type (Ln). Control loop type 4, for example, indicates
a control loop with 2 KSDs connected in parallel to a single motor with a double winding. The
main winding is commutated by a master (type 1), and the parallel winding by a slave (type 4).
The following values are possible:
y
1
Master control loop
2
Control loop of a position--controlled slave (“Slave Pos”)
3
Control loop of a torque--controlled slave (“Slave Torq”)
4
Control loop for parallel winding with 2 KSDs connected in parallel to a single motor
6
Force control, servo gun force control
In the case of 2 KSDs connected in parallel to a single motor, it is not possible to connect
the resolver of the motor to a CAN bus.
2.1.23 $LOOP_TYPE_ATTRIBUTE[ ]
Additional characteristics of the control loop
Data type
int
min
Value
1
Unit
[ ]
Value
max 18
Assignment
----
Bit array!
Required for certain Loop_types (currently only $Loop_type[Ln]=5) for the detailed
definition of linked characteristics.
Default value = 0
This machine datum is used exclusively for KUKA--internal development purposes.
2.1.24 $MASTER_LOOP[Ln]
Selection of the higher--level master control loop
Data type
int
min
Value
1
Unit
[ ]
Value
max 18
Assignment
----
$MASTER_LOOP[Ln]=y
In the case of slave control loops, this variable indicates the number of the higher--level
master control loop. The permissible combinations are described in the documentation about
the master/slave functions.