Kühtreiber MAKin 320 P HF Скачать руководство пользователя страница 25

 

25

EN

 TIG DC 

 - Setting the DOWN SLOPE function

The function is used for the continuous termination of the welding process. 

Together with the END CURRENT function, it prevents crater formation at the 

end of the weld when properly adjusted. During the set time, the welding 

process decreases continuously current to the end current value. Activation is 

performed by pressing the control n-encoder one after the other.

TIG HF

N-coder

TIG DC

 TIG DC 

 - Setting the END CURRENT function 

The function indicates the current value at which the welding process ends. 

Together with the DOWN SLOPE function, it prevents the crater from forming 

at the end of the weld when properly adjusted. Activation is performed by 

pressing the control n-coder one after the other. 

TIG HF

N-coder

TIG DC

 TIG DC 

 - Setting the POST-GAS function

The function ensures protection of the weld after the welding process is com-

pleted and at the same time it cools the tungsten electrode. The low duration 

of the function can affect the ignition quality of the arc due to oxidation of the 

electrode. Activation is performed by pressing the control n-coder one after 

the other.

TIG HF

N-coder

TIG DC

 TIG DC 

 - Setting the 2-STROKE function

The function indicates how the welding process is activated. When using this 

mode, it is necessary to press the control button during welding to send a 

signal to activate the welding process. Pressing the control button starts the 

welding process and activates the sequence of functions. Activation is perfor-

med by pressing the control n-coder one after the other.

TIG HF

N-coder

TIG DC

 TIG DC 

 - Setting the 4-STROKE function

The function indicates how the welding process is activated. In this mode, it 

is necessary to press the control button, which sends a signal to activate the 

welding process. The PRE-GAS function is then activated, followed by START 

CURRENT. When the button is released, the welding process starts by swit-

ching to WELDING CURRENT and activating other active functions gradually. 

To complete the welding process, press the control button again to activate 

the DOWN SLOPE function and then the END CURRENT function. When the 

button is released, the welding process ends and the POST-GAS function is 

activated.  

TIG HF

N-coder

TIG DC

 TIG DC 

 - Setting the PULSE function

Setting the value determines the lower welding current I

2

 of the pulse. Activa-

ting this function reduces the thermal load on the welded material. Activation 

is performed by pressing the control n-coder one after the other. 

TIG HF

N-coder

TIG DC

Содержание MAKin 320 P HF

Страница 1: ...1 N VOD K OBSLUZE SVA OVAC STROJ INSTRUCTION FOR USE WELDING MACHINE CZ EN MAKin 320 P HF AC DC...

Страница 2: ...visn organizaci kter m dostupn p slu n vy baven a speci ln vy kolen person l Ve ker na e stroje a za zen jsou p edm tem dlouhodob ho v voje Proto si vyhrazujeme pr vo na zm nu b hem v roby Popis Stroj...

Страница 3: ...lkov ovl d n UP DOWN 10k potenciometr bezdr tov ovl d n Chlad c modul ANO Gener tor ANO TIG DC P edfuk plynu s 0 2 Startovac proud A ANO UP SLOPE s 0 10 DOWN SLOPE s 0 10 Koncov proud A ANO Dofuk plyn...

Страница 4: ...ut PULS bodov n Pozice 12 Deaktivace vodn ho chlazen Pozice 13 Aktivace vodn ho chlazen Pozice 14 P ep n n zp sobu chlazen Pozice 15 P ep n n re im Pozice 16 P ep n n funkc Pozice 17 Ovl dac n kod r P...

Страница 5: ...e prov d pomoc ovl dac ho n kod ru Pro nastaven je nutn m t aktivn funkci nastaven sva ovac ho proudu Aktiva ce se prov d postupn m stisknut m ovl dac ho n kod ru Kontrolka hl proudu Nastaven sva ovac...

Страница 6: ...e prov d po stupn m stisknut m ovl dac ho n kod ru MMA Nastaven funkce ANTI STICK p ilepen elektrody Funkce sni uje sva ovac nap t na 5 V p i vyhodnocen zkratu na v stupn ch svork ch p i p ilepen elek...

Страница 7: ...li n mu zah v n wolframov elektrody a n sledn tvorb kuli ky na jej m konci N sledkem vytvo en kuli ky doch z k nestabiln mu ho en sva ovac ho oblouku a ztr ty mo nosti zen sm ru oblouku Pokud jsou ve...

Страница 8: ...Aktivac t to funkce doch z ke sn en tepeln ho zat en sva ovan ho ma teri lu Aktivace se prov d postupn m stisknut m ovl dac ho n kod ru TIG HF Ovl dac n kod r TIG AC triangl TIG AC kvadr t TIG AC sinu...

Страница 9: ...postupn m stisknut m ovl dac ho n kod ru TIG HF Ovl dac n kod r Sva ovac proud TIG DC Kontrolka hlavn ho proudu TIG DC Nastaven funkce PRE GAS p edfuk plynu Funkce slou k zaji t n ochrann atmosf ry p...

Страница 10: ...ru po ukon en sva ovac ho procesu a z rove chlad wolframovou elektrodu N zk doba trv n funkce m e m t vliv na kva litu zapalov n sva ovac ho oblouku z d vodu oxidace elektrody Aktivace se prov d postu...

Страница 11: ...pulzu doch z ke sn en tepeln deformace materi lu a z en svarov l zn Aktivace se prov d postupn m stisknut m ovl dac ho n kod ru TIG HF Ovl dac n kod r TIG DC TIG DC Vypnut funkce PULSE SPOTWELDING Op...

Страница 12: ...tepeln ho zat en i penetrace sva ovan ho materi lu TIG HF Ovl dac n kod r TIG DC TIG DC SPOT Nastaven funkce POST GAS dofuk plynu Funkce zaji uje ochranu svaru po ukon en sva ovac ho procesu a z rove...

Страница 13: ...en ch postup 3 Stiskn te tla tko na ho ku 4 Pro ukon en sva ovac ho procesu uvoln te tla tko na ho ku Pr b h sva ovac ho procesu u TIG HF obr 1 1 P ibl en wolframov elektrody ke sva ovan mu materi lu...

Страница 14: ...lektrody Spr vnou volbou wolframov elektrody a jej p pravou ovlivn me vlastnosti sva ovac ho oblouku geometrii sv ru a ivotnost elektrody Elektrodu je nut n jemn brousit v pod ln m sm ru dle obr zku 4...

Страница 15: ...ov n b n oceli a n zkolegovan ch slitin Tyto daje nemaj absolutn hodnotu a jsou pouze informativn Pro p esn v b r sledujte in strukce poskytovan v robcem elektrod Pou it proud z vis na pozici sv e n...

Страница 16: ...Sva ovac kabely nejsou p ipojeny P ipojte oba sva ovac kabely Sva ovac kabely jsou po kozeny Opravte vym te po kozen kabel Zemn c kabel nen p ipojen Zkontrolujte p ipojen zemn c ho kabelu 6 Oblouk lze...

Страница 17: ...appropriate equip ment and specially trained personnel All our machines and equipment are subject to long term development Therefore we reserve the right to make changes during production Description...

Страница 18: ...control UP DOWN 10k potentiometer wireless control Cooling unit Yes Generator Yes TIG DC PRE GAS s 0 2 Starting current A ANO UP SLOPE s 0 10 DOWN SLOPE s 0 10 End Current A Yes POST GAS s 0 10 Pulse...

Страница 19: ...LS function Position 11 Switching off PULS SPOT Position 12 Deactivate liquid cooling Position 13 Activate water cooling Position 14 Control button Position 15 Switching modes Position 16 Function swi...

Страница 20: ...ng function must be active for the setting Activation is done by pressing the control n encoder one after the other Main current indicator Welding current setting MMA method N coder Welding current MM...

Страница 21: ...at is active for the set time After the set time has elapsed the welding arc ignites Activation is performed by pressing the control n coder one after the other TIG HF N coder TIG AC triangle wave TIG...

Страница 22: ...at and subsequently form a ball at its end As a result of the formation of a ball the welding arc becomes unstable and the possibility of controlling the arc direction is lost If black spots are visib...

Страница 23: ...TIG HF N coder TIG AC triangle wave TIG AC square wave TIG AC sinusoid wave TIG AC Turn off the PULSE function Press the mode switch repeatedly to the OFF position TIG HF N coder TIG AC triangle wave...

Страница 24: ...tivates the function that is active for the set time After the set time has elapsed the welding arc ignites Activation is performed by pressing the control n coder one after the other TIG HF N coder T...

Страница 25: ...DC Setting the 2 STROKE function The function indicates how the welding process is activated When using this mode it is necessary to press the control button during welding to send a signal to activa...

Страница 26: ...mode switch repeatedly to the OFF position TIG HF N coder TIG DC TIG DC Setting the CYCLE function The function allows switching between two currents Activation is only possi ble in 4 stroke mode TIG...

Страница 27: ...Setting POST GAS function The function ensures protection of the weld after the welding process is com pleted and at the same time it cools the tungsten electrode The low duration of the function can...

Страница 28: ...hing the tungsten electrode to the welded material 2 Press the button on the burner high frequency HF to ignite the arc 3 Welding process 4 Finishing the welding process and activating the DOWN SLOPE...

Страница 29: ...in Figure 4 Figure 5 shows the effect of grinding the electrode on its service life Picture 4 Picture 5 Figure 5A Fine and even grinding of the electrode in the longitudinal direction Lifetime up to 1...

Страница 30: ...low the instructions provided by the manufacturer of the electrodes The current used depends on the position of the welding and the joint type and increases according to the thickness and dimensions o...

Страница 31: ...the machine 5 The arc cannot be ignited The welding cables are not connected Connect both welding cables The welding cables are damaged Repair replace damaged cable The ground cable is not connected C...

Страница 32: ...Termistor Thermistor 23 Hlavn transform tor Main transformer 25 Dno Bottom Seznam n hradn ch d l List of spare parts Popis Description 26 PCB kondenz tor PCB condenser 27 PCB n sobi PCB multiplier 28...

Страница 33: ...4 Typ stroje Machine type 5 Jm no a adresa v robce Name and address of manufacturer 6 V robn slo Serial number 7 Normy Standards 8 Proud p i zat en Load current 9 Nap t p i zat en Voltage under load...

Страница 34: ...34 Elektrotechnick sch ma Electrical scheme...

Страница 35: ...robku Type MAKin 320 P HF AC DC V robn slo stroje Serial number V robce Producer Raz tko OTK Stamp of Technical Control Department Datum Date of production Kontroloval Inspected by Z znam o proveden...

Страница 36: ...36 V robce si vyhrazuje pr vo na zm nu The producer reserves the right to modification 04 2020...

Отзывы: