PERIODIC SERVICE
68
EVERY 250 HOURS SERVICE
Perform inspection and servicing for every 50 hours of
operation at the same time.
B
Checking fan belt tension
To avoid personal injury or death:
A
Only check the fan belt with the engine off and
the key removed.
1. Press the fan belt in the middle with a fingertip by a
force of about 10 kg. The belt tension is proper if the
belt deflects about 7 mm. If the tension is improper,
adjust the tension by loosening bolts and shifting
alternator.
2. Check the pulleys and the V-belts for damage and
wear.
Carefully check to see if the V-belts fit snugly into the
V-belt grooves.
3. If the V-belt has been stretched too much, nicked or
cracked, replace it.
A
If the engine is running with a loose fan belt, the belt
may slip, causing engine overheating or insufficient
battery recharging.
Always keep the fan belt properly tightened.
A
If the fan belt should break, the battery charge lamp
lights up.
Immediately stop the engine.
B
Checking radiator hoses and clips
To avoid personal injury or death:
A
Do not check radiator hoses until the engine
has cooled down.
Check to see if radiator hoses are in good condition and
the clips are properly fixed every 250 hours of operation
or six months, whichever comes first.
1. If clips are loose or water leaks, tighten the clips
securely.
2. Replace hoses and hose clamps every 2 years or
earlier if checked and found that hoses are swollen,
hardened or cracked.
(1) Bolt
(2) Bolt
(3) Alternator
(A) about 7 mm
(B) approx. 10 kg
(1) Radiator hoses
(2) Clips
Содержание R065
Страница 9: ...CONTENTS SERVICE HOUR METER 89 ...
Страница 10: ......
Страница 22: ...SAFE OPERATION 12 8 DANGER AND WARNING LABELS ...
Страница 23: ... 13 SAFE OPERATION ...
Страница 24: ...SAFE OPERATION 14 ...
Страница 25: ... 15 SAFE OPERATION ...
Страница 26: ...SAFE OPERATION 16 ...
Страница 28: ......
Страница 30: ...SERVICING OF WHEEL LOADER 2 1 Engine serial No ...