77
PERIODIC SERVICE
B
Changing coolant
To avoid personal injury or death:
A
Never open the plug immediately after the
engine has stopped, or hot coolant may rush
out, causing scalding.
1. Open the plug under the radiator to drain the coolant.
2. To drain the recovery tank, disconnect the pipe at the
bottom of the recovery tank.
3. Clean the radiator interior by pouring water into the
supply port and keeping the plug open until clean
water flows out of it.
4. Close the plug and fill the radiator and recovery tank
with a mixture of anti-freeze and water (50%/50%).
After filling, idle the engine for about five minutes, stop
the engine and make sure that the coolant level is up
to the filling nozzle of the radiator.
B
Replacing Intake Air line
Replace the hoses and clamps, if necessary.
(See "Checking Fuel and Intake Air Line" in "EVERY 250
HOURS SERVICE")
B
Replacing Radiator Hoses (Water pipes)
Replace the hoses and clips.
(See "Checking Radiator Hoses and Clips" in "EVERY
250 HOURS SERVICE" in "PERIODIC SERVICE"
section.)
PERIODIC PARTS REPLACEMENT
B
Replacing Air-Conditioner Pipes and
Hoses [CABIN type only]
To avoid personal injury:
A
Do not touch the water hoses or the heater with
your hand. You may get burned.
Replace air-conditioner pipes and hoses every two years.
If the hoses or pipes are swollen, hard or cracked, they
should be replaced. (Consult your local KUBOTA Dealer
for this service.)
(1) Plug
(1) Radiator cap
(1) Hoses
(2) Hose clamps
Содержание R065
Страница 9: ...CONTENTS SERVICE HOUR METER 89 ...
Страница 10: ......
Страница 22: ...SAFE OPERATION 12 8 DANGER AND WARNING LABELS ...
Страница 23: ... 13 SAFE OPERATION ...
Страница 24: ...SAFE OPERATION 14 ...
Страница 25: ... 15 SAFE OPERATION ...
Страница 26: ...SAFE OPERATION 16 ...
Страница 28: ......
Страница 30: ...SERVICING OF WHEEL LOADER 2 1 Engine serial No ...