Coin Mechanism related
Error
codes
Occurring Error
10
Coin-mech
communication error
11
Acceptor jammed error
15
Return switch error
16
Coin payout failure
17
Safety switch error
18
Pulse switch error
19
Acceptor error
20
Tube sensor error
25
Coin sensor error
26
Sensor A error
27
Sensor B error
28
Sensor C error
Reconnect harness.
If there seems to be no problem,
replace the coin mech.
Remove jammed coin.
If there seems to be no problem,
replace the selector or coin mech.
If there seems to be no problem,
replace the coin mech.
Remove jammed coin.
If there seems to be no jam,
replace the coin mech.
Reinstall coin tube cassette in
correct position.
If there seems to be no problem,
replace the coin mech.
Remove jammed coin.
If there seems to be no jam,
replace the coin mech.
Secure coin selector in correct
position.
If there seems to be no problem,
replace the coin mech.
If there seems to be no problem,
replace the coin mech.
If there seems to be no problem,
replace the selector or coin mech.
Check harness and connectors
for disconnection.
Check coin selector for jammed
coin.
Coin return lever stuck.
Check payout area for jammed
coin.
Check that coin tube cassette
is installed correctly.
Check payout area for jammed
coin.
Check that coin selector is
in correct position.
Check coin tube sensor.
Check coin selector for jammed
coin.
Inspect coin selector.
Insert coin of all types, check for correct reading.
Insert coin of all types, operate coin return lever,
check correct payout.
Check the function of "out of change" lamp by
filling and removing the coins in the tube.
Insert coin of all types, check for correct reading.
Insert coin of all types, operate coin return lever,
check correct payout.
Check point
Action
Recovery verification
Sold-out
columns
All Columns
Error codes and Corrective Actions
TPK
Vending
Corporation
Co.,
Ltd.