Faulty starter.
Faulty battery.
broken.
Reference
--------
..
C
.
irc
.
u it
.
sh
_
orted.
[
rt:
Glow plug indicator shorted.
75
KiSC issued 09, 2007 A
Pinion does not pop out by the
attraction force of magnet switch.
Over-running clutch slips.
95
Poor contact of contact plate.
85,86
Poor contact between brush and commutator.
92, 94
Armature and field coil shorted.
85,86
93. 94
Bearing worn.
95,96
Main switch faulty.
Faulty magnet switch.
85.86
87
Screw spline rusted.
Faulty battery.
Battery not sufficiently charged.
Poor terminal contact.
Grounded poorly.
Incorrect wiring between battery and glow plug.
Glow plug indicator disconnected.
Glow plug disconnected.
Main switch or starter switch faulty.
Shorted between glow plug indicator and glow plug.
Glow plug shorted.
87
Glow plug cable shorted.