background image

Rotor Name

Nominal Capacity

Tube size (mm)

diam. x length

Maximum Speed

rpm

Maximum RCF

x

g

Tube Rack Adaptor

Code No.

AF-2018

18 x 1.5/2mL

9.5〜11×36〜42

15,000

20,630

18 x 0.5mL

7〜7.9×25〜34

15,000

18,110

055-7590

AF-2724A

24 x 1.5/2mL

9.5〜11×36〜42

16,000

23,470

12 x 0.5mL

7〜7.9×25〜34

16,000

19,180

12 x 0.2mL PCR

5.9〜6.3×20〜24

16,000

16,890

AF-2730

30 x 1.5/2mL

9.5〜11×36〜42

14,000

20,820

14 x 0.5mL

7〜7.9×25〜34

14,000

17,530

14 x 0.2mL PCR

5.9〜6.3×20〜24

14,000

16,430

AF-2236

36 x 1.5/2mL

9.5〜11×36〜42

15,000(14,000)

21,880(19,060)

12 x 0.2mL PCR

5.9〜6.3×20〜24

15,000(14,000)

15,340(13,370)

36 x 0.5mL

7〜7.9×25〜34

15,000(14,000)

19,620(17,090)

055-7590

AF-2048A

48 x 1.5/2mL

9.5〜11×36〜42

12,000(11,500)

15,780(14,490)

48 x 0.5mL

7〜7.9×25〜34

12,000(11,500)

14,330(13,160)

055-7590

*2

*2

*2

*2

AF-2018

18 x 1.5/2mL

・  

Quick acceleration within 10 

seconds

AF-2048A

48 x 1.5/2mL

・  

Useful for centrifuging a 

large number of samples.

Micro Rotor

Table of Rotors, Buckets and Tube Racks for Model 6200

Autoclavable 

Autoclavable

Autoclavable

Autoclavable

Autoclavable

AF-2730 and AF-5004CS rotors are certified as “Biosealed rotors” 
by CAMR (U.K.).
Even if tubes get broken, samples will not come out of the rotor. 
These rotors can be used for inspections of BSE, SARS, etc.

AF-2724A

24 x 1.5/2mL, 12 x 0.5/0.2mL PCR

・  

4 types of tubes (1.5/2mL, 

0.5mL, 0.2mL PCR) can be 
used without adaptors.

・  

RCF with 20,000 xg is 

effective for BSE tests.

AF-2236

36 x 1.5/2mL, 12 x 0.2mL PCR

・  

4 types of tubes (1.5/2mL, 0.5mL, 0.2mL PCR) 

can be used without adaptors.

・  

Caps of 1.5/2mL tubes can be set in the 

same direction, which is useful for 
experiments.

AF-2730

Biosealed Rotor
30 x 1.5/2mL

・  

4 types of tubes (1.5/2mL, 

0.5mL, 0.2mL PCR) can be 
used without adaptors.

 

For RCF indication, please refer to the instruction manual.

 The temperature of sample is maintained at 4℃ at maximum speed of rotation.

  When AF-2236 or AF-2048 rotor is used, The temperature of sample is 

maintained at 4℃ at speed of rotation indicated in the brackets ( ), and at 8℃ 
at maximum speed.

*1

*1

*1

*1

*1

AF-512

12 x 5mL

AF-5004CH

4 x 50mL Conical tube

15,000rpm/22,140xg

Protective structure for 
50mL conical tube caps 
prevents the tubes 
from getting broken. 
(patented)

AF-5004CS

Biosealed Rotor
4 x 50mL Conical tube

Various tubes can be 

used with adaptors.

AF-5004CA

4 x 50mL Conical tube

AF-5004RA

4 x 50mL

・ 

10mL biohazard-proof 

with sealing adaptors 
(code no. 055-4280) can 
be used.

AF-3806A

6 x 38mL

Rotor Name

Nominal Capacity

Tube size (mm)

diam. x length

Maximum Speed

rpm

Maximum RCF

×

g

Tube Rack Adaptor

Code No.

AF-5004CH

4 x 50mL conical tube

30 x 117

15,000

22,140

4 x 15mL conical tube

17 x 121

15,000

21,130

055-1250

AF-5004CS

4 x 50mL conical tube

30 x 117

12,000

14,970

4 x 15mL conical tube

17 x 121

12,000

14,490

055-1280

AF-5004CA

4 x 50mL conical tube

30 x 117

12,000

14,170

4 x 15mL conical tube

17 x 121

12,000

13,520

055-1280

AF-5008C

8 x 50mL conical tube

30 x 117

10,000(9,500)

13,420(12,110)

8 x 15mL conical tube

17 x 121

10,000(9,500)

13,190(11,910)

055-1280

AF-512

12 x 5mL

15 x 59

15,000

20,880

AF-1408A

8 x 14mL

17 x 75〜100

12,000

14,330

AF-5004RA

4 x 50mL

28.5〜29 x 102〜115

15,000(14,000)

21,880(19,060)

4 x 12mL

15.8〜16.4 x 103〜110

15,000(14,000)

20,630(17,970)

055-7410

4 x 10mL

16〜16.3 x 79〜92

15,000(14,000)

20,630(17,970)

055-4280

AF-3806A

6 x 38mL

25〜25.6 x 87〜103

15,000(14,500)

21,880(19,060)

*1  0.2mL PCR tubes can be used with adaptors (code no.055-0500).
 

When 055-0500 adaptor is used, it could not be used at maximum speed. 

*2  This is a speed of outside tubes. Please contact us for more details.
*3  Iwaki, Greiner, Corning, Sarstedt, Sumiron, Vioramo, BD falcon, Fisher, Labcon and Nunc's tubes  (cap diam. 36mm or less) can be used.
*4  Nalgene tubes (catalogue no.3110-0500/PPCO, 3110-9500/PPCO, 3117-9500/PC) require adaptors (code no.055-1110).
*5  Biobic 5mL sampling tubes and Watson 5mL mega tubes are applicable.
*6  Falcon tubes (catalogue no.352059) can be used.
*7  These sealing adaptors can be used for anti-biohazard.

AF-1408A

8 x 14mL

* 6

* 5

*3,4

*3

*3

*3

*5

*6

*7

Fixed Angle Rotor (for Conical Tubes)

Fixed Angle Rotor (Middle Volume)

Autoclavable

Autoclavable

Autoclavable

Autoclavable

Autoclavable

Autoclavable

AF-5008C

8 x 50mL Conical tube

 The number of times allowed for autoclaving is limited. For more details, please contact us.

Rotor has prescribed operating life cycle, after that the rotor must be replaced.
For more details, please contact us.

Содержание 6200

Страница 1: ...6200 www centrifuge jp Hybrid High Speed Refrigerated Centrifuge ...

Страница 2: ...sity gradient centrifugation also available RCF xg setting operation function and step centrifugal force function can be applied Integrator function can optimize centrifugal effect G sec value integrated RCF value can be measured and the operation with this value is possible Timer can be set up to 990 seconds minutes During the hold condition elapsed running time is displayed Safety quality Equipp...

Страница 3: ... 5 2mL 9 5 11 0 x 36 42 15 600 12 x 0 5mL 7 0 7 9 x 25 34 13 330 055 7590 12 x 0 2mL PCR 5 9 6 3 x 20 24 11 320 055 0500 6200 Multi rotor MF 2236A 3 types of buckets can be used with this rotor This helps save cost and time of centrifugation High Speed Centrifugation Maximum speed 15 000rpm Maximum RCF 18 870xg Swinging bucket 24 x 1 5 2 mL 15 000 rpm 18 360xg Fixed angle bucket 24 x 1 5 2 mL 15 0...

Страница 4: ...rotective structure for 50mL conical tube caps prevents the tubes from getting broken patented AF 5004CS Biosealed Rotor 4 x 50mL Conical tube Various tubes can be used with adaptors AF 5004CA 4 x 50mL Conical tube AF 5004RA 4 x 50mL 10mL biohazard proof with sealing adaptors code no 055 4280 can be used AF 3806A 6 x 38mL Rotor Name Nominal Capacity Tube size mm diam x length Maximum Speed rpm Max...

Страница 5: ... TERUMO Neo tube by NIPRO and Vacutainer by BD 6 In case of using glass tubes rubber cushion code no 024 1400 is necessary 7 Sealing caps and o rings sillicon are equipped with buckets Autoclavable at 121 SF 240 Max 4 000 rpm Max 2 610 xg SF 240 Max 4 000 rpm Max 2 610 xg Plate Nominal Capacity Plate size mm Maximum Speed rpm Maximum RCF xg Adaptor Code No 2 x PCR plate 6 x MTP 2 x DWP 86 W 128 D ...

Страница 6: ...No 055 0760 055 1180 tube 1 5mlTube tube 4 2mlTube BT 03 055 4800 BT 07 055 6900 BT 08 055 4740 055 1190 055 0770 tube 6 1 5ml tube 6 2 5ml tube 6 3 5ml tube 7 1 7ml tube 7 2 7ml tube 7 3 7ml tube 9 8mlCPT tube 18 10ml 2 BT 02 053 5840 BT 06 055 0260 1 BT 13 055 4770 055 1200 055 1180 tube 22 1 100ml tube 22 2 100ml tube 12 175ml tube 14 225ml 055 0760 055 6070P 055 1170 tube 11 50ml Table of Roto...

Страница 7: ...l 055 1150 055 0750 055 0740 055 4780P tube 10 15ml BT 11 055 4760 tube 21 50ml tube 12 175ml tube 13 200ml tube 14 225ml BT62 1 250ml BT62 2 250ml tube 25 1 tube 25 2 tube 25 3 500mL tube BT 14 055 4850 BT 14 055 4850 055 0780 055 0780 055 1210 n BT 11 055 0430 BT 12 055 0440 BT 12 055 0450 055 0810 055 0800 055 0790 6200 This convenient tube rack can accommodate various sizes such as 5 mL 7 mL 1...

Страница 8: ...nt Instruction Service Manual when operating centrifuges Copyright 2020 KUBOTA CORPORATION X SEP Printed in Japan www centrifuge jp 29 9 Hongo 3 chome Bunkyo ku Tokyo 113 0033 Japan Tel 81 3 3815 1331 Fax 81 3 3814 2574 The term of supplying spare parts for repair is 7 years after discontinuation of production except spare parts which we are unable to procure This catalogue is not for distribution...

Отзывы: