Operating in emergency situations
In case of emergency, you can switch off the engine and lower the boom manually.
Engine stop knob
If the engine cannot be stopped with the key, it can be stopped man-
ually.
To stop the engine, pull the knob (1) until the engine stops.
After the engine has stopped, push in the knob.
Manual lowering of the front attachments
The boom and arm can be lowered in case of an engine failure or if malfunctions occur in the hydraulic system.
Turn the starter switch to the RUN position.
If necessary, lower the boom and the arm with the control levers as described in the "Operating the controls
during excavation work" section (page 88).
The excavator may only be taken back into operation after the malfunction has been eliminated.
Make sure nobody is standing in the lowering area before starting the emergency lowering proce-
dure.
The lowering function is available only for a short time, as it is controlled by the accumulator in the
hydraulic system. The cylinders extend or retract by force of gravity.
STOP
STOP
Содержание 50740
Страница 8: ...Tables 6 RG268 8135 6 01 2019...
Страница 32: ...30 RG268 8135 6 01 2019 Safety rules...
Страница 48: ...46 RG268 8135 6 01 2019 Description of the excavator...
Страница 62: ...60 RG268 8135 6 01 2019 Assembly and functions...
Страница 128: ...126 RG268 8135 6 01 2019 Operation...
Страница 135: ...Troubleshooting RG268 8135 6 133 01 2019...
Страница 136: ...134 RG268 8135 6 01 2019 Troubleshooting...
Страница 139: ...Maintenance RG268 8135 6 137 01 2019...
Страница 174: ...172 RG268 8135 6 01 2019 Safety inspection...
Страница 193: ...Accessories RG268 8135 6 191 01 2019...
Страница 194: ......